Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T04CM02623
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/10/2004 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 07/06/2004 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T04CM02623 7/6/04 2804 E. DRACHMAN #2 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FLOOR PLANS: 1. PLEASE INDICATE THE LOCATIONS OF THE BRACED WALL PANELS AND THE HOLD DOWNS. SEE R602.10.6 . 2. SHEAR PANEL & BRACED WALL SCHEDULE / 1 ; PROVIDE THE NAILING FOR THE INTERMEDIATE STUDS. SEE R602.10 . 3. SHEAR PANEL & BRACED WALL SCHEDULE / 1 ; CLARIFY "STD 8". STHD 8? 4. SHEAR PANEL & BRACED WALL SCHEDULE / 1 ; THE ANCHOR BOLTS @ 36" O.C. APPEAR TO BE IN CONFLICT WITH R602.10.6 . PLEASE JUSTIFY. STRUCTURAL PLANS: 1. JUSTIFY THE SINGLE SPAN OUTRIGGERS. IF EXTENDING THEM MORE THAN ONE RAFTER BAY, JUSTIFY THE NOTCHED TOP CHORD OF THE COMMON TRUSSES. 2. SHOW THE LOCATION OF THE ATTIC ACCESS EITHER ON THE FRAMING PLAN OR THE FLOOR PLAN. SEE R807 . 3. PROVIDE MANUFACTURER'S CALCULATIONS AND DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. ELEVATIONS: 1. WEST ELEVATION ; PLEASE SIZE THE GABLE VENT. DOES THE EAST ELEVATION HAVE A GABLE VENT? SECTIONS - DETAILS - MISC. NOTES: 1. SECTION & ELEVATION NOTES, #2 / 2 ; HOW DOES THE CEILING GWB COMPLY WITH TABLE R702.3.5 FOOTNOTE D? 2. 2 / 2 ; PLEASE RE-NUMBER THE FOOTING DETAIL AND THE OVERHANG DETAIL. MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC. PLEASE CHANGE THE CODE REFERENCES. 2. PLEASE SIZE THE SUPPLY AIR AND THE RETURN AIR. SEE M1602 AND M1603 . ELECTRICAL PLANS: 1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC. 2. ELECTRIC NOTE #3 ; 1/0 APPEARS TO BE INADEQUATE FOR 380 AMPS. SEE TABLE E3503.1 . 3. PANEL SCHEDULE , CIRCUIT 1,3 ; #2 APPEARS INADEQUATE FOR 200 AMPS. SEE TABLE E3503.1 . 4. RISER DIAGRAM ; #4 APPEARS TO BE INADEQUATE FOR THE GROUNDING ELECTRODE CONDUCTOR. SEE TABLEE3503.1 . 5. RISER DIAGRAM ; PLEASE SIZE THE BONDING CONDUCTOR TO THE METAL WATER AND GAS LINES. SEE TABLE E3503.1 . 6. PLEASE NOTE THAT THE LIGHT FIXTURE OVER BATH TUB IS REQUIRED TO BE LISTED AS APPROVED FOR USE IN WET AREAS. SEE E3903.8 . 7. PROVIDE A RECEPTACLE AT THE BACK OF THE DWELLING. SEE E3801.7 . IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/08/2004 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 07/08/2004 | SUE REEVES | REJECT SHELF | Completed |