Review Date Reviewer's Name Type of Review Description Status Comments
10/13/2006 MARTIN BROWN FIRE REVIEW Denied Exterior exit stairs at South propery line need fire need fire protection per IFC Chapter 7 and IRC. So does West wall of South unit.
10/18/2006 DAVID RIVERA ZONING HC SITE REVIEW Passed
10/18/2006 DAVID RIVERA ZONING REVIEW Denied DSD Zoning Review Transmittal



TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: T04CM02415
143 W Palmdale St
Multifamily use - 2- SFRs

TRANSMITTAL DATE: October 18, 2006

COMMENTS: This site has been reviewed for full code compliance. The following items must be addressed by the Board of Adjustment for variance approval.

1. The side yard building setbacks must be the greater of 10 feet or three-fourths the height of the structure. The required building setbacks could not be verified because building elevation drawings were not included with the site plan. Both buildings are existing and therefore the set backs are existing.

a. Building one: West Side yard setback must be a minimum of ten feet or three quarters the height of the structure. The owner proposes 5' (existing bldg. setback).

b. Building one: East Side yard bldg. setback must be a minimum of ten feet or three quarters the height of the structure. The owner proposes 6'-10" (existing bldg. setback).

c. Building two: West Side yard setback must be a minimum of ten feet or three quarters the height of the structure. The owner proposes 4'-4" (existing bldg. setback).

d. Building two: East Side yard setback must be a minimum of ten feet or three quarters the height of the structure. The owner proposes 0'-0" and 3'-6" (existing bldg. setbacks).

e. Building two: South Side yard setback must be a minimum of ten feet or three quarters the height of the structure. The owner proposes 4'-5" and 7'-0" (existing bldg. setback). Also a staircase has been built within the building setback and over an easement. (The staircase may have to be removed.) Fire safety concerns, Permits Plus comments by Dave Mann "Exterior exit stairs at South property line need fire protection per IFC Chapter 7 and IRC. So does West wall of South unit."

2. Parking for this development is based on the number of bedrooms per unit. Unit one is designed with five bedrooms and unit two is designed with six bedrooms. The parking requirements are as follows. For units with four or more bedrooms 2.5 spaces are required. The total number of parking spaces required (includes both units) is five spaces.


A minimum four-foot concrete sidewalk is required between the parking spaces and the building. Also the parking area will have to be paved and striped and wheel stops provided to keep vehicles from overhanging onto the sidewalk.

When four or more parking spaces is provided on site the vehicular use area must be designed to meet the design criterion in Development standards 3-05. The design criteria include paving, striping, on site maneuvering area, two-way PAALs, landscaping, screening and pedestrian sidewalks. It is clear that the six parking spaces cannot be provided on site and that the on site maneuvering area, PAAL width, landscaping and screening cannot be provided. A variance to eliminate one parking space, on site maneuvering area, backing out onto the street, PAAL width, pedestrian sidewalks, possibly landscaping and screening will be required.

Additional comments by other reviewing agencies are likely and could affect the site and variance request items. Please address all possible comments and resubmit for final variance comments if necessary. Please keep in mind that the Board of Adjustments addresses only LUC requirements.

3. The lot coverage calculation must include the vehicular use area. Please revise the calculation to reflect this additional coverage. If the vehicular use area is included in the square footage used f or the calculation please list the vehicular use area separately.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.


DSD Zoning Review Transmittal

TO: Development Services Department
Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: T04CM02415
143 W Palmdale St
Multifamily use - 2- SFRs

TRANSMITTAL DATE: November 14, 2006

COMMENTS: The following comments have been provided as a supplement to the comments dated October 18, 2006. Paragraph two under comment two was incorrectly worded. The comment should have reflected the requirement for "five or more parking spaces" in the first sentence and "five parking spaces" in the third sentence. The paragraph in question has been revised to reflect these changes. Please see the following.


Revised paragraph:

When five or more parking spaces is provided on site the vehicular use area must be designed to meet the design criterion in Development standards 3-05. The design criteria include paving, striping, on site maneuvering area, two-way PAALs, landscaping, screening and pedestrian sidewalks. It is clear that the five parking spaces cannot be provided on site and that the on site maneuvering area, PAAL width, landscaping and screening cannot be provided. A variance to eliminate one parking space, on site maneuvering area, backing out onto the street, PAAL width, pedestrian sidewalks, possibly landscaping and screening will be required.
10/24/2006 ANDREW CONNOR NPPO REVIEW Denied Provide acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property. Photographs of the site are necessary for NPPO approval per DS 2-15.2.0.C
10/24/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. The following requirements apply to developments, which provide more than four (4) motor vehicle parking spaces per LUC 3.7.2.3.

2. A landscape plan per DS 2-07.0. to verify that entire site meets current minimum requirements.

3. A street landscape border, per LUC 3.7.2.4, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress.

4. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4

5. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border per LUC 3.7.2.4.

6. A 30" continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I.

7. Provide acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property. Photographs of the site are necessary for NPPO approval per DS 2-15.2.0.C

8. Include with re-submittal variance documentation. Indicate on the lower right hand corner of the site plan, the variance case number, date of approval, and any conditions imposed.
11/08/2006 JASON GREEN ENGINEERING REVIEW Denied DATE: November 8, 2006
SUBJECT: Remodel Apartments to Single Family Residence- Site Plan Review
TO: Kevin Petrick
LOCATION: 143 W Palmdale St., T14S R13E Sec36, Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: T04CM02415


SUMMARY: Engineering Division of Development Services Department has received and reviewed the submitted site plan. The site plan was reviewed for Development Standards compliance. The site plan is not approved at this time. Please address the following comments:


SITE PLAN COMMENTS:

1) DS Sec.2-02.2.1.A.2: Provide the property description along with the subdivision book and page for the above referenced property.

2) DS Sec.3-05.2.3.C: Provide wheel stop curbing in the parking stall that are designed and located so as not to impede pedestrian circulation. Refer to this standard for barrier requirements.

3) DS Sec.3-05: Provide an on-site vehicular use area designed to meet the criterion in this section. If the requirements for the vehicular use area can not be meet then a variance must be applied for to eliminate on-site maneuvering area, PAAL width, pedestrian sidewalks and other requirements found within this section.

4) DS Sec.2-02.2.1.A.11: Revise the site plan to label the width of the shared ingress/egress location for the subject property.

5) DS Sec.3-01.3.3.A: Revise the site plan to show the required 5-foot wide sidewalk along Palmdale Street.

6) DS Sec.2-02.2.1.A.12: Revise the site plan to show the required 4-foot pedestrian circulation path that must be located between the existing building and the parking area.

7) DS Sec.2-02.2.1.A.12: Revise the site plan to label the 4-foot minimum pedestrian circulation path that is required from the parking area to the existing back building.

8) DS Sec.2-02.2.1.A.16: Provide a detail for the location and type of drainage structure, label and dimension proposed scuppers, that are used for collecting onsite roof drainage at all pedestrian sidewalk. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow. Provide a drainage statement showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk.

9) DS.2-01.2.1.A.19: Provide the recordation information for the existing right-of-way for Palmdale Street.

10) DS Sec.2-02.2.1.A.20: Revise the site plan to clearly label and show the existing 8-foot water and 8-foot communication easement, provide recordation information on the site plan.

11) DS Sec.2-01.2.1.A.23: Provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and Page number.

12) DS Sec.3-01.2.7 A: Revise the site plan to reflect handicap access ramps with truncated domes. Please refer to this standard and the figures provided for additional curb access ramps requirements.

13) Provide water-harvesting areas, depressed 6-inches, shown in plan view to provide for onsite drainage. Refer to the City of Tucson Water Harvesting Guidance Manual, Ordinance # 10210, for recommendation on how to construct and maintain the required water harvesting areas


GENERAL COMMENTS:

Please provide a revised site plan that address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

Further comments may be generated upon resubmittal of the site plan.

For any questions or to schedule a meeting, call me at 791-5550, extension 1189.




Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services