Permit Number: T04CM02380
Parcel: 122050600

Address:
4342 E EDISON ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T04CM02380
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2004 JIM TATE ENGINEERING REVIEW Approved DATE: September 1, 2004
ACTIVITY NUMBER: T04CM02380
PROJECT ADDRESS: 4342 E. Edison
PROJECT REVIEWER: James C. Tate, P.E., CFM

The following items must be revised or added to the Site Plan.

Resubmittal Required: Site Plan, Grading Plan

GENERAL COMMENTS:

1. A Flood Use Permit is required prior to Site Plan approval. PRIOR REVIEW COMMENT

2. Include estimated cut and fill quantities on the plan. Cut and fill quantities exceeding 50 cubic yards will require a Grading Plan and Permit. IBC Chapter 36
PRIOR REVIEW COMMENT
The footprint of the new proposed structure as specified on the plan is 1784 square feet. The fill needed to bring the floor up to the required FFE will be in excess of one foot. Assuming one foot of fill, the fill required under the foundation would be 66 yards. The total amount of fill required for this project will have to be more than 50 yards. Therefore a grading plan and permit is required.
Grading plan requirements can be found in the IBC Chapter 36.

3. Sheet 3 Note 7 of the Site Plan specifies the FFE as 12 inches above existing grade. This is incorrect. The Hydrology Statement specifies the FFE as at or above 2459.1 ft. NGVD-29. Remove Note 7. PRIOR REVIEW COMMENT

4. It appears that the intent is to elevate the building on stem walls. However, the plan is not clear. Elevation on fill requires the building to be set back 25 ft. from the fill line unless a registered professional engineer recommends a closer distance and it is approved by the city. Elevation on fill also requires bank protection to safeguard against flood incurred erosion. Again, in the absence of a grading plan, it can not be determined how the building is proposed to be elevated.
09/02/2004 JIM TATE ENGINEERING REVIEW Approved FUP No. T04OT01317
Grading Permit No. T04BU02205
09/07/2004 GERRY KOZIOL WWM REVIEW Approved
09/15/2004 Terry Stevens BUILDING-RESIDENTIAL REVIEW Approved SEEE PREVIOUS COMMENTS

Final Status

Task End Date Reviewer's Name Type of Review Description
09/16/2004 SUE REEVES OUT TO CUSTOMER Completed