Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T04CM02201
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/20/2004 | Robert Sherry | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise fixture connection schedule to include the new hose bibb (in darkroom) and the ½" CW connection to the vacuum pump. Revise pipe sizes as required. Indicate if the hot water has been sized using Section 610.12 or Section 610.13, UPC 1994. Reference Section 610.1, UPC 1994. 2. Appliances to be directly connected to the water supply system (e.g. the vacuum pump and the darkroom equipment) that do not have listed, integral backflow preventers or integral air gaps may require reduced pressure principle backflow preventers. Please submit equipment sheets for determination. Reference Section 603.0, UPC 1994. 3. Provide listing information for the proposed water filter and show how it is to be installed. Reference Section 103.2.3, UPC 1994. 4. Clarify the size of the plumbing vent over OP. #2 - 2" or 2-1/2"? 5. Provide protection for the PVC pipe exposed to sunlight. Reference Section 313.5, UPC 1994. |
| 05/20/2004 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Revise the total amount of outside air for HP-2 to comply with the requirements of Section 403.2.3, IMC 2000. 2. Show that the restroom ventilation complies with Section 403.2.1, IMC 2000. |
| 05/20/2004 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 05/20/2004 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 05/24/2004 | JIM EGAN | FIRE | REVIEW | Approved | |
| 06/04/2004 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Completed | |
| 06/10/2004 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/10/2004 | EGRANT1 | OUT TO CUSTOMER | Completed |
| 06/10/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |