Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2004 Neil Saunders BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project #T04CM02150

1. 2&3/S-1: Provide a positive connection for ledgers on bearing and non-bearing walls.
2. 1/S-2: Veneer cannot be used as a structural element and therefore it is not suitable to hang a ledger from. Minimum structural masonry unit is 6". Revise detail.

If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.