Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM02150
Parcel: 124031780

Address:
1809 E 7TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T04CM02150
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2004 Neil Saunders BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project #T04CM02150

1. 2&3/S-1: Provide a positive connection for ledgers on bearing and non-bearing walls.
2. 1/S-2: Veneer cannot be used as a structural element and therefore it is not suitable to hang a ledger from. Minimum structural masonry unit is 6". Revise detail.

If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/15/2004 LISA LESNY OUT TO CUSTOMER Completed
09/15/2004 ANGIE SHOFFSTALL REJECT SHELF Completed