Permit Number: T04CM02055
Parcel: 11307160A

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T04CM02055
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/01/2004 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: October 1, 2004
ACTIVITY NUMBER: T04CM02055
PROJECT NAME: Four-plex Addition
PROJECT ADDRESS: 1509 East Hedrick Drive
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN


1. The site plan is still difficult to read. Site plans must be legible and must maintain legibility after being microfilmed. It is recommended to remove the landscaping, texturing and hatching from the site plan. There are general notes on the plan that don't need to be on the plan. This clutters the plan and makes plan difficult to read. For plan clarity it is recommended to remove unnecessary plan content. Again this plan is difficult to read and the purpose of a site plan is to have a legible document that can be microfilmed and maintain legibility.

2. Remove the general note, "Less than 50 cubic yards of cut and fill."

3. When showing spot elevations include finish grade elevations for all proposed sidewalks and the PAAL. Because the entire site is within a floodplain the city of Tucson requires sidewalks to be flood free from all storm discharges for up to a ten year event consequently the spot elevations and finish grade elevation are needed to determine the difference in height. Revise the plan as necessary. DS 2-02.2.1.A.23., DS 2-08.4.1.E.

Above is a comment from the second submittal. Because the water surface elevation is 2377.24 the proposed finish grade elevations for the sidewalks are too low. Sidewalks must be flood free for up to a ten year event. The potential of the sidewalks becoming flooded in a ten year event is high. Revise the sidewalks to be 6" above asphalt (PAALs).

4. Include more finish grades for the PAAL.

5. It is noted that in your response letter it states to see Solid Waste Department letter. The letter was not found. Solid waste proposals not meeting DS 6-01 require a Development Standard Modification Request to be processed and approved prior to site plan approval. For information on the DSMR process contact Patricia Gehlen at 791-5550 extension 1179.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/05/2004 LISA LESNY OUT TO CUSTOMER Completed
10/05/2004 ANGIE SHOFFSTALL REJECT SHELF Completed