Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM02006
Parcel: 112031390

Address:
2910 E FARR ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM02006
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/02/2004 PATRICIA GILBERT ENGINEERING REVIEW Approved
06/03/2004 LEE JACOBS LANDFILL REVIEW Approved
06/04/2004 GERRY KOZIOL WWM REVIEW Approved
06/21/2004 Christy Foreman BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS PROJECT #T04CM02006
06/22/2004 2910 E. Farr St.

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.
SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2000 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.
GENERAL REQUIREMENTS:
1. All plans shall be legible and a scale no smaller than ΒΌ inch = 1-foot shall be used for all floor plans, framing plans and elevations. Details and cross sections shall be a minimum 3/8 inch = 1-foot scale.
2. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia & (1) blue line shall be returned along with all redline prints. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.
FOUNDATION PLANS:
1. Locate and detail all footings for the following:
- Fireplace - zero clearance?
FLOOR PLANS:
1. Show fireplace location, hearth size and materials, per R1003.10 or R1004.2. For factory built or zero clearance fireplaces, provide cut sheets, make, model number and the approval number of the approved testing agency (IE: ICBO #), per R1002 (specifications not required to be on plan). Factory built fireplaces shall comply with UL-127. For masonry fireplaces, show cross-section, per R100.
STRUCTURAL PLANS:
1. Provide complete roof framing plans. Clarify glulam stops at new post and footing and it is over framing to existing ridge. Clarify span dimension of glulam.
2. Specify and detail all over-framing. If solid sheathing is used on the lower trusses, provide minimum openings of 22" by 30" for access and ventilation into over-framed areas (>30 S.F.). If solid sheathing is not used on lower trusses, provide details for bracing of top chord of lower trusses.
3. Completely detail all connections and cross-reverence to the foundation and framing plans:

- Beam to post - Clarify connection for two glulam beams at post.
ELEVATIONS:
1. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply.
2. Note and dimension that the fireplace chimney must terminate a minimum of 2' above any point of roof within 10' measured horizontally and not less than 3' above the point where the chimney passes through the roof, per R1001.6.
SECTIONS - DETAILS - MISC. NOTES:
1. Detail masonry fireplaces. Provide dimensioned and noted sections and firebox plan. State flue size, dimension hearth width and reinforcing. Note and detail anchorage tie straps fastened to a minimum of four joints with 2-1/2" bolts embedded into masonry and engaging the outer reinforcing bars with a 6" hooked extension. See table and figure R1003.1. Clarify type of fireplace.
PLUMBING PLANS:
1. Show the size of vents.
2. Gas: Provide the length of line to each appliance, BTU demand of each appliance, size of each branch, total demand, and total developed length from meter to the most remote appliance on the system per UPC 1217.2. Gas to fireplace appears to be undersized each unit = 25,000 therefore total BTU's is incorrect.
ELECTRICAL PLANS:
1. Relocated receptacles on new family room / new kitchen north wall appears to be located beyond max. distance allowed between receptacles.
2. Show locations of smoke detectors per R317. Note that all smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. When ceiling finish materials are removed in existing construction, existing bedrooms shall be in compliance. When ceiling finish materials are not removed, existing bedrooms shall be equipped with battery operated smoke detectors per R317.1.1.
MODEL ENERGY CODE:
NOTE: If addition is < 20% of total square footage of dwelling, you are not required to meet MEC requirements.
1. Provide energy calculations per the 1998 IECC and comply with IRC chapter 11.
2. Call out on the plan the "R" values of insulation, as well as the "U" values of the windows and doors in compliance with the energy calculations provided.
If you have any questions, please contact your assigned plans examiner Christy Foreman at 791-5550, extension 1113.
NOTE: As of 2-02-01 the City of Tucson has adopted the 2000 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. All model plans shall reference these codes.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/24/2004 TAMI ACHONG OUT TO CUSTOMER Completed
06/24/2004 ANGIE SHOFFSTALL REJECT SHELF Completed