Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE ONLY
Permit Number - T04CM01921
Review Name: COMMERCIAL-BLDG/FIRE ONLY
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/11/2004 | JIM EGAN | FIRE | REVIEW | Approved | |
| 05/18/2004 | Martin Haeberle | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Retaining wall foundation may not encroach on public property. Revise plans 2. Retaining wall steel reinforcement sizes differs from sizes utilized in calculations. Please clarify 3. Calculations indicate the use of a soils report. A soils report was not included in submittal. Please clarify 4. Handrails/guardrails to be designed to resist a load of 50# per linear foot as required by section 1607.7.1 IBC. Provide calculations justifying proposed design. 5. Special inspection required for proposed welding. Indicate on plans 6. Electrical approval required for proposed lighting and conduit installation. |
| 06/01/2004 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1106 OR EMAIL AT LBUCZYN1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS. 1. Provide catalogue cut sheets and lighting fixture schedule for new lighting fixtures. 2. Identify panel and circuit number, and account for any new electrical load, for all new lighting fixtures. 3. Specify lighting fixture suitability for their location, be it a wet location or a damp location. 4. Demonstrate that new lighting fixtures are in compliance with the Outdoor Lighting Ordinance. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/03/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 06/02/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |