Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T04CM01762
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/16/2004 | BLANCA ESPINO | ENGINEERING | REVIEW | Approved | |
| 04/16/2004 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 04/19/2004 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide access and working space for the water heater. Reference Section 511.2, UPC 1994. 2. Provide description of the "Open Site Drain" . Reference Sections 301.1.1 and 804.1, UPC 1994. 3. The "Open Site Drain" may not be located above the ceiling. Reference Section 804.1, UPC 1994. 4. Provide calculations to show that the water supply piping has been sized in accordance with Section 610.0, UPC 1994. 5. Show the size of the water supply pipe to which the new plumbing fixtures are being connected. 6. Drawing note #8 indicates that the T&P relief line is to be terminated over the mop sink (in conflict with drawing note 13 and domestic water riser diagram). The mop sink is not an approved termination point for the T&P relief. Reference Section 608.5, UPC 1994. 7. Show how the new drainage piping is coordinated with the existing drainage piping. Reference Section 103.2.3, UPC 1994. 8. The new floor cleanout does not provide adequate service for the drain pipe from the mop sink. Install cleanout for the mop sink. Reference Section 707.4, UPC 1994. |
| 04/19/2004 | NEAL SAUNDERS | BUILDING-COMMERCIAL | REVIEW | Needs Review | |
| 04/19/2004 | EGRANT1 | WWM | REVIEW | Needs Review | |
| 04/19/2004 | JIM EGAN | FIRE | REVIEW | Approved | |
| 04/19/2004 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 04/19/2004 | EGRANT1 | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
| 04/19/2004 | ROBERT SHERRY | WATER | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/17/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |