Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM01759
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/23/2004 | Jim Egan | FIRE | REVIEW | Approved | |
| 04/30/2004 | Daniel Castro | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next Submittal, which states how all Zoning Review Section comments Regarding the Land Use Code and Development Standards were Addressed. CODE SECTION/DEVELOPMENTSTANDARD 1. The following comments are based on a greater than 25% building area expansion resulting in a full code compliance review of the entire site. All calculations encompass the entire site, whether existing or proposed. Revise calculations where applicable on sheet T1 to reflect existing and proposed development. (D.S. 2-02.2.2.B) 2. Remove the legal description for the adjacent parcel to the east on sheet T1. (D.S. 2-02.2.1.A.2) 3. a) Handicap parking sign is located within the four (4) foot sidewalk. Relocate so as to not obstruct vehicular or pedestrian circulation. b) Please note if access aisles are flush with pedestrian sidewalks or if required, provide ramps. Detail access ramps. (ICC/ANSI A117.1-1998 Sec 405) 4. Under the project data block bicycle parking, please note the number and class type required and provided. (D.S. 2-02.2.2.A.4) 5. Per D.S. 2-08.4.1.A, at least one (1) sidewalk must be provided to the building from each street on which the project has frontage (Fourteenth Street). The minimum four (4) foot sidewalk should be located to minimize any conflict with vehicular access to the project. (D.S. 2-02.2.1.A12) 6. D.S. 3-05.2.2.B.1, requires a five (5) foot wide pedestrian refuge area along the north side of the new warehouse (between the PAAL and the building). 7. If applicable, provide a detail of existing and/or proposed free-standing signage/billboard and outdoor lighting on the site plan. (D.S. 2-02.2.1.A.13) (D.S. 2-02.2.1.A.25) 8. Under the loading zone calculation on sheet T1 Project Data, revise 25,000 to 20,000. (LUC Sec. 3.4.5.2) (D.S. 2-02.2.2.A.5) 9. Existing use noted under the project data block sheet T1 states "none", and the existing use noted under the site data block on sheet C1 states "commercial". Revise one or the other for consistency. (D.S. 2-02.2.1.A.31) 10. Add the applicable "subject to" section (LUC Sec. 3.5.10.1) to the proposed use listed under the site data block on sheet C1. (D.S. 2-02.2.1.A.31) 11. Note on sheet C1, states that a variance has been issued for an existing chain link fence with vinyl slats and constantino wire. As a general note, please add the following: board of adjustment variance case number, date of approval, variance/s granted, and any conditions imposed. 12. Please note the building area expansion calculation. (D.S. 2-02.2.2.A.6) 13. All requested changes must be made to the site and landscape plans, where applicable. (D.S. 2-07.2.1.A) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 05/03/2004 | DAN CASTRO | HANDICAP-SITE | REVIEW | Denied | a) Handicap parking sign is located within the four (4) foot sidewalk. Relocate so as to not obstruct vehicular or pedestrian circulation. b) Please note if access aisles are flush with pedestrian sidewalks or if required, provide ramps. Detail access ramps. (ICC/ANSI A117.1-1998 Sec 405) |
| 05/10/2004 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Indicate contour intervals along with north arrow and scale. D.S. 2-02.2.1.A.1 2. Indicate existing sight visibility triangles for local to a local. Near side 180', Far side 110'. D.S. 2-02.2.1.A.10 3. Fully dimensioned loading space(s) and maneuvering area(s). D.S. 2-02.2.1.A.14 4. Delineate limits of the 100-year floodplain and water surface elevation as per drainage statement. D.S. 2-02.2.1.A.15 5. Indicate drainage patterns, proposed finish floor elevation and finish grades. D.S. 2-02.2.1.A.16 6. Indicate if street is Public or Private. Closed unused driveways. Show adjacent driveways. D.S. 2-02.2.1.A.18 7. If applicable, indicate all easements of record to be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20 8. Indicate existing and proposed utility lines. D.S. 2-02.2.1.A.21 9. If applicable, indicate location and orientation of existing major physical features, such as railroad tracks and drainageways. D.S. 2-02.2.1.A.22 10. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and Page number. D.S. 2-02.2.1.A.23 |
| 05/11/2004 | JOE LINVILLE | NPPO | REVIEW | Approved | Prev appr. exc. per microfilm. |
| 05/11/2004 | Joseph Linville | LANDSCAPE | REVIEW | Denied | 1) Revise the plans as requested by other agencies. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/14/2004 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 05/14/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |