Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM01735
Parcel: 12111208A

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM01735
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2004 MELISSA POULIN WWM REVIEW Approved
05/14/2004 David Witt BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T04CM01735

5/14/04 1645 N. SANTA ROSA AVE.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.
2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

SITE PLAN:

1. INDICATE THE LOCATION OF GAS, WATER, ELECTRIC AND SEWER OR SEPTIC LINE ON THE PROPERTY, AND
WHERE THEY ENTER THE BUILDING. PROVIDE THE LOCATION OF YOUR WATER METER AND SEPTIC SYSTEM
IF IT EXISTS.OR IF NONE ARE UNDER THE ADDITION, PLEASE ADD A NOTE TO THAT FACT.

FOUNDATION:

1. PLEASE PROVIDE A LANDING OUTSIDE THE NORTH EXIT DOOR. SEE R312.1.2.1 .

FLOOR PLANS:

1. HOW DOES THE WINDOW OVER THE TUB COMPLY WITH R308?

2. HOW IS EMERGENCY ESCAPE AND RESCUE (R310) ACCOMPLISHED? PLEASE PROVIDE THE SIZE OF THE VENT SECTION OF THE CASEMENT WINDOW "A" AND THE SILL HEIGHT.

SECTIONS - DETAILS - MISC. NOTES:

1. PROJECT DATA, BUILDING INFORMATION / G1.1 ; PLEASE INCLUDE THE 2000 I.R.C. AND THE '94 U.P.C. AS AMMENDED IN THE APPLICABLE CODES.

2. 2 / A2.2 ; PLEASE CLARIFY THE "SLOPE DOWN…….." NOTE.

3. ROOF FRAMING / S1.1 ; KEY NOTES 3 AND 5 APPEAR TO CONFLICT. PLEASE JUSTIFY THE BOLTS OR CONSIDER THE I.R.C. LEDGER BOLT SCHEDULE ON FIGURE R606.10(1) .

4. FOUNDATION KEY NOTE 3 / S1.1 ; PLEASE NOTE THAT A SPECIAL INSPECTION IS REQUIRED FOR THE EPOXY HERE AND IN OTHER DETAILS.

5. 7,8 / S3.1 ; SHOULD THE NOTE REFERRING TO THE FOOTING'S WIDTH REFER TO THE SCHEDULE ON 3.1 INSTEAD OF THE PLAN?

6. 7 / S3.1 ; PLEASE SPECIFY THE STEM WALL'S WIDTH.

7. 2 / S3.2 ; JUSTIFY THE 8d NAILS JOINING THE DOUBLE PLATE.

8. 5 / S3.2 ; SPECIFY THE JOIST HANGER.

9. DO THE LEDGER BOLTS CONFLICT WITH LEDGER BOLTS ON THE FRAMING PLAN?

PLUMBING PLANS:

1. PLUMBING FIXTURE SCHEDULE / P1.1 ; PLEASE CHECK THE FIXTURE UNITS FOR A PRIVATE WATER CLOSET. SEE U.P.C. TABLE 7-3 .

ELECTRICAL PLANS:

1. INDICATE THE EXTERIOR RECEPTACLES AS G.F.C.I. PROTECTED.

2. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11.



IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
05/19/2004 TAMI ACHONG OUT TO CUSTOMER Completed
05/18/2004 TAMI ACHONG REJECT SHELF Completed