Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM01663
Parcel: 119043530

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM01663
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/27/2004 MELISSA POULIN WWM REVIEW Approved
05/11/2004 David Witt BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T04CM01663

5/11/04 376 W. VETERANS BLVD.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.


SITE PLAN:

1. INDICATE THE LOCATION OF GAS, WATER, ELECTRIC AND SEWER OR SEPTIC LINE ON THE PROPERTY, AND
WHERE THEY ENTER THE BUILDING. PROVIDE THE LOCATION OF YOUR WATER METER AND SEPTIC SYSTEM
IF IT EXISTS.

FLOOR PLANS:

1. PROVIDE EGRESS FROM THE ADJACENT EXISTING BEDROOM. SEE R310. IS IT EXISTING?

2. CLARIFY "WOOD BURNING HEAT BOX". THE HEARTH EXTENSION IS REQUIRED TO EXTEND FULL DEPTH FOR 8" OR 12" PAST THE FIRE BOX OPENING. SEE R1003.9 THROUGH R1003.10 .

3. FIREPLACES: - INDICATE FIREPLACE LOCATION, HEARTH SIZE AND MATERIALS, PER R1003.10 OR R1004.2
- FOR FACTORY BUILT OR ZERO CLEARANCE FIREPLACES, PROVIDE CUT SHEETS, MAKE,
MODEL NUMBER AND THE APPROVAL NUMBER OF THE APPROVED TESTING AGENCY
(IE: ICBO #), PER R1002 ALL SHALL COMPLY WITH UL127.
- FOR MASONRY FIREPLACES, SHOW CROSS-SECTION, PER I.R.C.CHAPTER 10.


STRUCTURAL PLANS:

1. SPECIFY DESIGN CRITERIA ON PLANS. VALUES FOR FLOOR DEAD LOAD AND LIVE LOAD, ROOF DEAD LOAD
AND LIVE LOAD.

2. SPECIFY WHICH SERIES 12" T.J.I. IS TO BE USED.







SECTIONS - DETAILS - MISC. NOTES:

1. PROVIDE A CROSS SECTION OF THE "WOOD BURNING HEAT BOX".

2. SECTION A-A / 1 ; ARE DETAILS 7 AND 8 / 2 MIS-NUMBERED?

3. SECTION A-A / 1 ; PLEASE PROVIDE THE ROOF PITCH.

4. SECTION A-A / 1 ; DETAIL HOW THE RAFTER SPACE WILL BE PROVIDED. SEE R806.

5. SECTION A-A / 1 ; HOW DO THE WOODEN FLOOR JOISTS COMPLY WITH R323 ITEM 1 ?

6. SECTION A-A / 1 ; HOW DOES THE UNDER FLOOR SPACE COMPLY WITH R408 FOR FOR VENTILATION AND ACCESS?

7. 1 AND 3 / 2 ; SPECIFY THE JOIST HANGERS.

8. DETAIL MASONRY FIREPLACES. PROVIDE DIMENSIONED AND NOTED SECTIONS AND FIREBOX PLAN. STATE
FLUE SIZE, DIMENSION HEARTH WIDTH AND REINFORCING. NOTE AND DETAIL ANCHORAGE TIE STRAPS
FASTENED TO A MINIMUM OF FOUR JOINTS WITH 2-1/2" BOLTS EMBEDDED INTO MASONRY AND ENGAGING
THE OUTER REINFORCING BARS WITH A 6" HOOKED EXTENSION. SEE TABLE AND FIGURE R1003.1.

9. 3 AND 4 / 2 ; HOW DOES THE CEILING GYP BOARD COMPLY WITH TABLE R702.3.5 FOOTNOTE D ?

10. FLOOR AND ROOF FRAMING / 2 ; PLEASE SPECIFY THE 12" T.J.I.

PLUMBING PLANS:

1. JUSTIFY THE EXISTING WATER DISTRIBUTION SYSTEM'S ABILITY TO CARRY THE NEW FIXTURE UNITS.

2. WATER CLOSETS REQUIRE A 3" (MIN.) DRAIN. SEE U.P.C. TABLE 7-5.

3. WATER CLOSETS REQUIRE A 2" (MIN.) VENT. SEE U.P.C. TABLE 7-5.

4. PLUMBING CODE NOTE 3 / 3 ; THE NON-ABSORBENT SURFACE AT TUBS AND SHOWER SHOULD BE 72" ABOSE THE FLOOR. SEE R307.2 .

5. PLUMBING CODE NOTES 4,5,6, AND 7 / 3 ; PLEASE MOVE THESE NOTES TO ELECTRICAL NOTES.

ELECTRICAL PLANS:

1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC.

2. PLEASE NOTE THAT THE LIGHT FIXTURES IN THE SHOWER AND OVER THE TUB ARE TO BE LISTED AS APPROVED FOR USE IN WET AREAS.

3. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED
OUTLET BOXES SHALL BE USED, PER E4001.6.

4. PLEASE PROVIDE A SMOKE DETECTOR IN THE AREA IMMEDIATELY OUTSIDE THE BEDROOM. SEE R317.1 ITEM 2.

5. PLEASE PROVIDE SMOKE DETECTORS FOR THE EXISTING DWELLING. SEE R317.1.1 .


IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
05/11/2004 LISA LESNY OUT TO CUSTOMER Completed
05/11/2004 ANGIE SHOFFSTALL REJECT SHELF Completed