Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T04CM01623
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/03/2004 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 05/20/2004 | David Witt | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T04CM01623 5/21/04 3745 E. 25TH ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. IS THE EXISTING ELECTRIC SERVICE TO THE EXISTING RESIDENCE OVERHEAD? IF SO, WILL THE ROOF CLEARANCE BE ADEQUATE? 2. INDICATE THE LOCATION OF GAS, WATER, ELECTRIC AND SEWER OR SEPTIC LINE ON THE PROPERTY, AND WHERE THEY ENTER THE NEW BUILDING. 3. THE MASTER BEDROOM IS REQUIRED TO HAVE AN EXIT DIRECTLY TO THE OUTSIDE. THE SCREENING ON THE PORCH PRECLUDES THE 6068 EXIT. IS THE SILL OF THE 6020 A MAXIMUM OF 44" A.F.F. ? IS THE VENT SECTION 20" WIDE? IS THE OPENING 5 SQ. FT. MINIMUM? SEE R310. FOUNDATION: 1. PLEASE LOCATE AND SPECIFY ANY REQUIRED HOLD DOWNS. SEE R602.10.6 . FLOOR PLANS: 1. LOCATE AND IDENTIFY SHEAR WALL TYPES AND LOCATIONS. PROVIDE NAILING SCHEDULE AND HOLD DOWNS. SEE R602 . 2. IS THE 2020 XO REQUIRED TO BE SAFETY GLASS? SEE R308 . 3. THE MEC VALUES LISTED DIFFER FROM THE ENERGY CODE ANALYSIS AND THE MINIMUM DEFAULT VALUES LISTED IN TABLE 1102.1 FOR A H.D.D. OF 2100. STRUCTURAL PLANS: 1. FRAMING PLAN / A3 ; PROVIDE THE HEADERS FOR THE FRONT BEARING WALL. 2. PROVIDE MANUFACTURER'S CALCULATIONS AND DATA FOR PRE-FAB TRUSSES AND GLULAM BEAMS. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS CALCULATIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS. ELEVATIONS: 1. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY. 2. NOTE AND DIMENSION THAT THE FIREPLACE CHIMNEY MUST TERMINATE A MINIMUM OF 2' ABOVE ANY POINT OF ROOF WITHIN 10' MEASURED HORIZONTALLY AND NOT LESS THAN 3' ABOVE THE POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF, PER R1001.6 3. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4. SECTIONS - DETAILS - MISC. NOTES: 1. SECTION A / A2 ; HOW DOES THE GYP. BOARD ON THE CEILING COMPLY WITH TABLE R702.3.5 FOOTNOTE D? 2. 1, 2, 3, 6 / D1 ; DESCRIBE THE BRACED WALL PANEL SHEATHING MATERIAL. SEE R602.10 . 3. 4 / D1 ; PROVIDE THE RAFTER TO BEAM CONNECTION. 4. 6 / D1 ; PROVIDE THE MINIMUM EMBEDMENT FOR THE ANCHOR BOLTS . SEE R403.1.6 . PLUMBING PLANS: 1. WATER SUPPLY AND DISTRIBUTION / A3 ; THE FIXTURE UNIT VALUES SHOULD BE TAKEN FROM THE UNIFORM PLUMBING CODE. 2. WATER SUPPLY AND DISTRIBUTION / A3 ; THE DEVELOPED LENGTH SHOULD BE MEASURED FROM THE WATER METER TO THE MOST REMOTE APPLIANCE INCLUDING THE VERTICAL MEASRUEMENTS. IF IT INCLUDES THE EXISTING RESIDENCE, IT'S FIXTURE UNITS SHOULD BE CONSIDERED IN ORDER TO CHECK THE EXISTING WATER SERVICE. 3. PLUMBING NOTES / A3 ; THE CODE OF REFERENCE SHOULD BE THE U.P.C. SOME NOTES REFER TO THE I.R.C. 4. THE GAS LINE APPEARS TO RUN PAST THE FURNACE. PLEASE CLARIFY. MECHANICAL PLANS: 1. THE REFERENCE TO THE I.M.C. IN THE "NOTE!" BELOW THE SPECIFICATION SHOULD REFER TO THE I.R.C. 2. IS THE 5 TONS OF AIR CONDITIONING WHAT YOU WANT TO USE ON THIS 818 SQUARE FOOT HOUSE? 3. THE 16" DIAMETER SUPPLY AND RETURN DUCTS APPEAR TO BE INADEQUATE FOR 5 TONS. SEE R1602 AND R1603. ELECTRICAL PLANS: 1. PLEASE PROVIDE A RECEPTACLE ON THE FAMILY ROOM WALL BETWEEN THE KITCHEN AND STOREAGE ROOM DOORS 2. PLEASE RELOCATE THE RECEPTACLE ON CIRCUIT 9 THAT'S IN THE FIRE PLACE. 3. RECEPTACLES ARE NOT TO BE INSTALLED FACE UP ON THE LAVATORY TOP NORTH OF THE NORTH LAVATORY BOWL. 4. THE RECEPTACLES THAT SERVE THE KITCHEN TOPS ARE REQUIRED TO BE GFCI PROTECTED. SEE R3802.6 . 5. PROVIDE A RECEPTACLE FOR THE WASHER / DRYER. ARE TWO RECEPTACLES REQUIRED. 6. IS A 20 AMP / 1-POLE ADEQUATE FOR THE 50 GALLON WATER HEATER? 7. HOW DOES THE LIGHT IN THE LINEN CLOSET COMPLY WITH R3903.11 ? IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/25/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 05/24/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |