Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T04CM01335
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/07/2004 | Terry Stevens | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T04CM01335 04/08/04 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. DIMENSION THE DEPTH INTO UNDISTURBED SOIL FOR EACH FOOTING TYPE AND CONDITION PER TABLE R403.1.----------DETAIL 3/S1.1-------MIN. 12" BELOW NATURAL GRADE 2. INTERIOR BEARING FOOTING MISSING FROM CROSS SECTION A/A2.1. 3. MIN. CLEARANCE FROM GRADE TO TOP OF SLAB IS 6"--------DETAIL 2/S1.1 INDICATES 4". FLOOR PLANS: 1. NOTE THAT BATHTUB AND SHOWER ENCLOSURES SHALL BE FINISHED PER p2710 WITH CERAMIC TILE, OR A LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE DRAIN PER R702.4 AND R307.2 2. DIMENSIONS MISSING FOR NEW PORCH. [BETWEEN POSTS, POSTS TO BUILDING, ETC.] STRUCTURAL PLANS: 1. INDICATE SIZE OF BEAM FOR NEW PORCH. 2. 6X12 BEAM OVER BEDROOM IS NOT ADEQUATE FOR LOADS IMPOSED. CHANGE OR SUBMIT CALCS. 3. INDICATE HOW BEAM WILL ATTACH TO EXISTING MASONRY WALL ALSO INDICATE POST OR BUILT UP MEMBER CONNECTION IN WOOD FRAME WALL. 4. SECTION A/A2.1 SHOWS INTERIOR NONBEARING WALL. THIS WALL IS A BEARING WALL AND ACCORDING TO ROOF FRAMING PLAN SHOULD BE LOCATED UNDER RIDGE BEAM. CLARIFY. 5. NOTE HANGERS BY TYPE, SIZE AND REQUIRED ATTACHMENT TO FRAMING MEMBERS.------DETAILS 5&6/S1.1. ELEVATIONS: 1. NOTE AND SPECIFY A COMPLETE ROOFING SYSTEM: ROOFING TYPE, GRADE OF MATERIALS AND METHOD OF INSTALLATION PER R905. 2. NOTE AND SPECIFY ALL ROOF SLOPES APPROPRIATE TO MATERIAL (SEE R905). SECTIONS - DETAILS - MISC. NOTES: 1. NOTE AND SPECIFY THE SIZE, SPACING AND LENGTH OF ANCHOR BOLTS FOR SILL PLATES.-----MIN. 7" EMBEDMENT PLUMBING PLANS: 1. SITE PLAN INDICATES GAS METER BEING RELOCATED. PLUMBING PLAN HAS NOTHING REGARDING GAS LINES. 2. GAS: PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE, BTU DEMAND OF EACH APPLIANCE, SIZE OF EACH BRANCH, TOTAL DEMAND & TOTAL DEVELOPED LENGTH FROM METER TO MOST REMOTE APPLIANCE ON THE SYSTEM PER UPC 1217.2 3. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH FROM METER. PROVIDE FOR ENTIRE HOUSE. USE THE 1994 UPC NOT THE IRC 2000. 4. ½" WATER LINES TO NEW BATHROOM INADEQUATE. 5. THE CITY OF TUCSON HAS NOT ADOPTED THE PLUMBING SECTION OF THE IRC 2OOO. THE CURRENT CODE EING USED IS THE 1994 UPC WITH THE STATE AMENDMENTS. ALL PLANS MUST REFERENCE TO THIS CODE. ELECTRICAL PLANS: 1. INDICATE AMPERAGE RATING OF EXISTING METER BASE. MUST MATCH NEW PANEL RATING. 2. PANEL SCHEDULE INDICATES A 200 AMP SUB PANEL------LINE DIAGRAM INDICATES 100 AMP------CLARIFY. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS @ 791-5550 EXT. 1112 |
| 04/12/2004 | MELISSA POULIN | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/23/2004 | DELMA ROBEY | OUT TO CUSTOMER | Completed |