Permit Number: T04CM01179
Parcel: 13706132A

Address:
5433 S 12TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T04CM01179
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/27/2004 Peter McLaughlin ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Arquitecto E. J. Ornelas
100 N. Stone Ave #1002
Tucson, AZ 85701
(520) 624-8102

FROM: Peter McLaughlin
Senior Planner
Development Services Dept.

FOR: Patricia Gehlen
Principal Planner
Development Services Dept.

PROJECT:
T04CM01179
El Merendero Plaza
Retail and Wholesale Plaza
5433 S. 12th Avenue
Site Plan Review (1st review)

TRANSMITTAL: April 28, 2004

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1. This project was reviewed as a change of use and greater than 25% expansion. Full code compliance is required for the entire site.
DS 2-02

2. All lettering must be a minimum of 12 point (0.12"). Revise all lettering and dimensions which do not meet this minimum standard for microfilming/archiving. Note: Further comments may be necessary once all dimensions and text are legible.

3. Provide the maximum slope of the handicapped ramp and access aisles to be provided.
ANS/ IBC

4. Add a note detailing the restrictions for the proposed retail use and the existing restaurant use. Retail General Merchandise Sales uses in the C-2 zone are subject to LUC 3.5.9.2.A. The restaurant use is subject to LUC 3.5.4.6.C and LUC 3.5.13.5.

DS 2-02.2.1.A.31
LUC 2.5.4.2.B.12

5. The location map is inaccurate. List the Township and Range for the map and revise to show correctly the location and names of streets bordering section 1, T. 15 S, R 13 E. 12th Avenue runs along the west edge of section. Nebraska Street does not run along the north line of the section. Liberty Ave does not run along the east line of the section. Also, revise legal description in location map to be correct and complete, including all lot numbers (Lots 18 and 19).
DS 2-02.2.1.A.2

6. Add a bicycle parking detail, which dimensions the bicycle parking layout, including maneuverability area on the plan per DS 2-09.
DS 2-02.2.1.A.9

7. Please add any existing and proposed easements, their width and their recordation information (docket and page reference numbers) to the site plan. Dimension the width of the electrical easement (keynote 20).
DS 2-02.2.1.A.20

8. Some keynotes are not correct or are not shown on the plan. For example, keynotes 14, 17 and 22 are not shown. Keynote 16 does not point to parking as stated in the site notes. Revise keynotes to be correct.

9. Dimension the width of all entrance/access drives. If the access drive from Canada street is one-way, signage must be provided to indicate "entrance only". Show the location of signage on the plan. DS 2-02.1A.13

10. No loading zone is shown on the site plan and it is indicated in the calculations that one is required and none are provided. A Board of Adjustment variance application approval is required for the waiver of loading zone requirement. Add the variance case number, date of approval, variances granted and conditions imposed to the notes.
DS 2-02.2.1.A.38
DS 2-02.2.1.A.14

11. Dimension all bldg. setbacks clearly on the plan. Keynote 33 states "Setbacks-see zoning tables" but no setbacks are provided in zoning tables. Revise to provide required and proposed bldg. setbacks. The MS&R setback along 12th Avenue is required to be the greater of 21 feet or height, dimensioned from back of future curb location. The setback to adjacent R-2 zoning to the east is required to be 1-½ times the height of exterior structure wall. This setback is not met. The waiver of setback requirement can be rolled into the B.O.A. variance application (see comment 10).
DS 2-02.2.1.A.38
LUC 3.2.6.4
LUC 3.2.6.5

12. Provide a copy of recorded cross-access and parking agreement between the two properties. Add docket and page information to the site plan for the agreement. The note under the drawing (adjacent to the north arrow) reads: "see cross section parking agreement (attached)" but no agreement was attached. Remove this note from the plan drawing and from the parking calculations, or clarify what it means.

13. Pedestrian circulation must be continuous and show direct connections between the buildings and adjacent rights-of way. Show pedestrian connection to 12th Avenue from the buildings. DS 2-08

14. Parking is not calculated correctly for the restaurant use. Revise calc to include all areas (excluding kitchen and storage) such as hallways and aisles. Revise the calculation to state the total square footage of the restaurant and provide a complete breakdown of public areas, subtracting out the square footage of the kitchen and storage areas in the calculation.
LUC 3.3.4
LUC 2-02.2.2.A.4

15. In addition to the maximum allowed floor area ratio (FAR), provide a proposed (FAR) calculation to the plan. The FAR is calculated as the building gross floor area ÷ site area. Also, the maximum allowed FAR per development designator 31 is 0.90, not 0.75 as stated. Please revise. DS 2-02.2.2.A

16. Some of the existing parking for the restaurant portion of the site does not meet code and may not be counted toward meeting required parking for the site. Parking may not be located within the right-of-way, within required landscape borders, or within sight visibility triangles. Vehicles may not back out on to 12th Avenue (MS&R). Revise plan and parking calculations. If the revised vehicle parking calculation shows a deficit in parking then a board of adjustment variance will be required (see comment 10). LUC 3.3.4

17. Provide a future site plan showing how the site will meet code once 12th Avenue is widened. An MS&R covenant must be recorded along with the future site plan, once it is approved. Provide documentation of recorded covenant and plan prior to issuance of permits. Place a note on the plan stating that the project is designed to meet the criteria of Sec. 2.8.3, MS&R setback zone. LUC 2.8.3







18. Show the location, size and height of any proposed freestanding signage. Also, indicate if any billboards exist on the site. DS 2-02.2.1.13



19. If any angled parking is to be provided, add the degree of the angled parking to show that minimum code requirements are met. LUC 3.3.7.2

20. Label and dimension existing/ future curbs and sidewalks from 12th Avenue centerline.
DS 2-02.2.1.A.21

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
04/28/2004 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Denied See zoning review comments.
04/30/2004 Joseph Linville LANDSCAPE REVIEW Denied 1) Revise the sheet numbers on the site plan(s). There appear to be two sheets labeled 1 of 2.

2) Revise the site plan to list the correct zoning for the property across Canada Street. C-2 is shown, R-2 is correct.

3) Revise the plans to include only on lot number per parcel. Currently, lot 133A is also labeled as lot 1, etc.

4) Revise the site and landscape plans to include loading areas and required screening. LUC 3.4.5, LUC Table 3.7.2-I

5) Detailed plans for Lot 133A are required. The entire site is subject to the provisions of LUC 3.7. Revise the plans such that both lots meet current code requirements.

6) Revise the site and landscape plans to include refuse storage areas. These areas may not be located in locations where landscape borders are also required. Provide screening per LUC Table 3.7.2-I for these areas.

7) Street landscape borders are required for lot 133A along Canada Street and S. 12th Avenue. LUC 3.7.2.4

8) Revise the landscape plan to include screening for lot 133A along Canada Street and S. 12th Avenue. LUC 3.7.3

9) Use the same symbol on the landscape plan and legend for Ruellia californica. DS 2-07.2.2

10) An interior landscape border is required along the southern boundary of Lot 133. LUC Table 3.7.2-I

11) Revise the landscape plan to include the number plants listed in the calculations for ground coverage. DS 2-07.2.2

12) Revise the description for Dalea capitata, this plant is typically less than 1' high and covers about 7-9 sq. ft.

13) Revise the plan keynote 3 on sheet one of the site, utility, and grading plan to clarify if the area is an easement or a public alley.

14) Locate keynote 30 on the plans.

15) Indicate if walls shown on the landscape plan are proposed or existing (keynote 3).

16) An irrigation plan is required. DS 2-07.2.2.C
05/04/2004 JOE LINVILLE NPPO REVIEW Approved Exception per 2002 PC aerial photo.
05/13/2004 Loren Makus ENGINEERING REVIEW Denied DATE: May 13, 2004
TO: Arquitecto E. J. Ornelas and Associates
SUBJECT: Site Plan, El Merendero Plaza
REVIEWER: Loren Makus
ACTIVITY NUMBER: T04CM01179

SUMMARY: The Site Plan was reviewed by Development Services Department, Engineering Division on May 13, 2004. The Site Plan was not approved at this time. Please address the following comments.

Site Plan Comments:
1) The driveway aprons on lot 1 do not meet the requirements of the Transportation Access Management Guidelines for the City of Tucson. Revise the site plan to meet the following requirements.
a) The maximum driveway width is 35 feet (30 feet at the property line).
b) Driveways must be at least 80 feet apart with a maximum of two driveways within 300 feet.
c) Maneuvering areas for the parking spaces must be on private property.
2) The existing solid waste container must be provided with an enclosure that meets the requirements of Development Standard (DS) 6-01.4.2.C. The enclosure must be outside of any Sight Visibility Triangles.
3) Clearly label existing and future SVTs. The dimensions on the near side SVTs and far side SVTs are reversed.
4) Provide a dumpster location and enclosure for the proposed retail and wholesale establishments. (DS 6-01.3.2.B) Show maneuverability to the solid waste container.
5) Provide estimated cut and fill quantities. (DS2-02.2.1.A.17)
6) The existing restaurant building is labeled with a finish floor elevation of 0.00. Provide a valid elevation.

Revise the Site Plan to address these comments and resubmit two copies for review. Include a letter explaining how each comment has been addressed.
Loren Makus, E.I.T.
Senior Engineering Associate
Engineering Division
Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
05/14/2004 CINDY AGUILAR OUT TO CUSTOMER Completed
05/14/2004 SUE REEVES REJECT SHELF Completed