Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04CM01105
Parcel: 120076980

Address:
507 W LINCOLN ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T04CM01105
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/27/2004 GERRY KOZIOL WWM REVIEW Approved
07/30/2004 Bruce Stevens BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS ACTIVITY #T04CM01105
08/11/2004 507 W. Lincoln St.

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.
SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2000 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.
FOUNDATION PLANS:
1. If you are using the assumed soil bearing value of 1500 PSF this must be stated on the foundation plan.
2. Footings for the new laundry room must be shown on the foundation plan, and must be sized per IRC.
STRUCTURAL PLANS:
1. Provide complete roof framing plan. Show size, spacing and span of all framing members. This must include the beams used at the porch.
2. Detail gable end bracing connections. Detail 2/3 should show diagonal or X bracing for gable end truss. Please detail your plan for bracing as well as the connections to be used at brace-to-wall and brace-to-truss connections.
3. Detail over-framed portion of roof. Show how over-framed area is to be supported. If solid sheathing is used on the lower trusses, provide minimum openings of 22" by 30" for access and ventilation into over-framed area.
4. Completely detail connection of ledger to wall framing. Must include some method of resisting pull-away from wall framing. This could be accomplished by the use of H2.5 connectors at each stud to the ledger, however you must determine what you intend to use and show this on your framing plan.
5. Identify all tie straps, framing anchors and joist hangers by type, size and required attachment to framing members.
STEEL LINTELS
Provide sizes of lintels to be used above doors and windows in masonry walls. The following sizes will work, but you must specify what you intend to use.
3' to 4' 2-3 ½"x3 ½" x ¼"
4' to 7' 2-4" x 3 ½" x 5/16"
7' to 9' 2-5" x 3 ½" x 5/16"
9' to 10' 2-5" x 3 ½" x 3/8"
10' to 12' 2- 6" x 4" x 3/8"
PLUMBING PLANS:
1. Gas: Provide the length of line to each appliance, BTU demand of each appliance, size of each branch, total demand, and total developed length from meter to the most remote appliance on the system per UPC 1217.2. Based on the figures shown on your plan, you will need at least a 1" feed from the gas meter, and could reduce to ¾" between furnace and range.
If you have any questions, please contact your assigned plans examiner Bruce Stevens at 791-5550, extension 1174.
NOTE: As of 2-02-01 the City of Tucson has adopted the 2000 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. All model plans shall reference these codes.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/24/2004 CINDY AGUILAR OUT TO CUSTOMER Completed
08/24/2004 ANGIE SHOFFSTALL REJECT SHELF Completed