Permit Number: T04CM01015
Parcel: 137105040

Address:
5530 S 12TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T04CM01015
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2004 JIM EGAN FIRE REVIEW Approved
03/30/2004 Peter McLaughlin ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: Metro Permit Express
1001 N. Alvernon Way #105
Tucson, AZ 85711
(520) 977-7187

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner
Development Services Dept.

PROJECT:
T04CM001015
Family Dollar
5530 S. 12th Avenue
Site Plan Review (1st review)

TRANSMITTAL: March 31, 2004


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This project was reviewed as a new use. Full code compliance is required.
DS 2-02

2. According to Assessors Records this site is made up of two parcels ("Drexel Terrace No. 1, South Half of Lot A" and "Drexel Terrace No. 1 North Half of Lot A"). In order to remove the property boundary running through the site, a lot combination is required prior to the approval of the site plan. Please provide documentation of lot combination including approved assessor's tax combo forms and notarized and recorded covenant. Add a legal description, which will read "Drexel Terrace No. 1, Lot A", to the site plan.
DS 2-02.2.1.A.2

3. In addition to the maximum allowed floor area ratio (FAR) provide a proposed (FAR) calculation in the project data. The proposed FAR would calculate the proposed building gross floor area (9180 sq ft) รท site area (40,041 sq ft) = 0.23 FAR.
DS 2-02.2.2.A

4. The site is within the Airport Environs Zone Airport Hazard District and NCD-65 for Tucson International Airport. Add a note to indicate that the elevation above median sea level (MSL) of the NW end of runway 11 L at T.I.A. is 2,575 feet. Along with building height proposed add the elevation above mean sea level of the site and add a note stating that this site plan complies with the Airport Environs Zone AHD and NCD-65.
LUC 2.8.5.7.A.1.c
LUC 2.8.5.6.A

5. Revise proposed use to read "General Merchandise Sales".
DS 2-02.2.1.A.312

6. Add a note stating that the proposal complies with LUC 2.8.3, Major Street and Routes (MS&R) Setback Zone.
LUC 2.8.3

7. Add docket and page number of recordation for the aerial and overhead easement along the west property line. Add any other existing and proposed easements and their recordation information (docket and page reference numbers) to the site plan.
DS 2-02.2.1.A.20

8. Indicate if any billboards exist on the site.
DS 2-02.2.1.A.13

9. Areas that are striped pedestrian paths which are not cross-walks must be made of concrete and be physically separated from adjacent PAALs/vehicle use area by use of raised concrete curbing. Please revise pedestrian connection to West Canada Drive to show physical separation except at crosswalks.
DS 3-01.3.3.B.5
DS 2-08.4.1

10. Dimension the standard parking spaces (typical) on the site plan.
DS 2-02.2.1.A.8

11. Dimension from street monument lines to existing and proposed curbs and sidewalks along 12th Ave and Canada Drive.
DS 2-02.2.1.A.21

12. If applicable, detail any proposed freestanding lighting. DS 2-02.2.1.A.25

13. Dimension the width of PAALs between the parking rows.
DS 2-02.2.1.A.11

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
03/31/2004 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Approved
04/01/2004 Andrew Connor LANDSCAPE REVIEW Denied 1) A 6' wall is required to screen the refuse storage area from adjacent residential property. LUC 3.7.2-I

2) The wall must be located on the property line. LUC 3.7.3.2.A

3) Include on landscape plan the 2 mitigated native mesquite tress per NPP plan.

4) Indicate on landscape plan the mesquite tree in ROW mentioned in NPP submittal. If the tree is to be removed then additional mitigation is required.

5) Landscape plan shall include irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

6) Slopes for the detention basin 3 feet and greater shall be a maximum of 4:1 per Page 78 DS 10-01

7) Show basin on landscape plan including slope elevations.

8) Show on the site plan downspout detail keynote #7 C1.1
04/01/2004 Andrew Connor NPPO REVIEW Approved
04/02/2004 LOREN MAKUS ENGINEERING REVIEW Denied DATE: April 2, 2004
TO: Metro Permit Express
SUBJECT: Site Plan and Grading Plan, Family Dollar, 5530 S. 12th Avenue
REVIEWER: Loren Makus
ACTIVITY NUMBER: T04CM01015 and TO4BU00501

SUMMARY: The Site Plan, Grading Plan and Drainage Report were reviewed by Development Services Department, Engineering Division on April 2, 2004. They were not approved. Please address the following comments.

Site Plan/Grading Plan Comments:
1) There appears to be a differential grading violation near the loading zone. Show that there will be less than two feet of fill within the outer 100 feet of the project. Otherwise meet the requirements of the grading ordinance.
2) Provide clear grading limits on the grading plan.
3) Provide estimated cut and fill quantities.
4) A letter from City of Tucson Environmental Services will be required to approve alley service for solid waste pickup.
Drainage Report
5) As indicated in the drainage report, provide results of the percolation tests. Demonstrate that the retained volume will percolate within 12 hours.

Revise the Site Plan, Grading Plan and Drainage Report to address all of these comments and resubmit two copies of each for review. Include a letter explaining how each comment has been addressed.

Loren Makus
Senior Engineering Associate
Engineering Division
Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
04/05/2004 LISA LESNY OUT TO CUSTOMER Completed
04/05/2004 SUE REEVES REJECT SHELF Completed