Permit Number: T04CM00768
Parcel: 121030380

Address:
5761 E LINDEN ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM00768
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/12/2004 GERRY KOZIOL WWM REVIEW Approved
03/15/2004 Bruce Stevens BUILDING-RESIDENTIAL REVIEW Denied 1. Note and detail tie straps, framing anchors and joist hangers by type, size and required attachment to framing members.
2. On the floor framing plan, note and detail double joists parallel to bearing partitions, double trimmers and headers, joists at framed openings, framing anchors for tail joists and header support, and bridging or blocking at the ends and bearing points of the floor joists.
3. Show details for all bearing and critical non-bearing conditions.
4. Indicate and note post sized, double or triple studs, and coordinate with foundation plan.
5. Detail all brace wall connections from the foundation to the roof plywood.
6. Provide brace wall details and notes for exterior frame walls and main cross-stud partitions, or use fully braced, per R602.10.3. A minimum panel width of 48" is required to effectively brace the partition. See table R602.10.3, category "C". If bracing does not comply, provide a lateral analysis or alternate design to be reviewed by the plan examiner. Wind forces for single story residences shall use 90 MPH, exposure "B". Two story residences or areas of higher wind shall use exposure "C".
7. Specify weight of roof system items (for example, weight of selected tile). Provide ICBO evaluation report number and manufacturer of all concrete or clay-type roofing.
Provide stairway connection details and stringer sizes. Pre-fabricated metal stair shall have manufacturer's specifications

Final Status

Task End Date Reviewer's Name Type of Review Description
03/17/2004 DELMA ROBEY OUT TO CUSTOMER Completed