Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T04CM00675
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2004 | Loren Makus | ENGINEERING | REVIEW | Denied | DATE: May 4, 2004 TO: Jim Fields Architect, Inc. SUBJECT: A-Access Self Storage Site Plan REVIEWER: Loren Makus ACTIVITY NUMBER: T04CM00675 SUMMARY: The Site Plan was reviewed by Development Services Department, Engineering Division on May 4, 2004. The site plan was not approved. Please address the following comments. Site Plan Comments: 1) As previously commented, show all existing structures including any structures (i.e. billboard) on "Lot B" "(Development Standard (DS) 2-02.2.1.A.8) 2) Provide estimated cut and fill quantities. (DS 2-02.2.1.A.17) 3) As previously commented, show finish grades throughout the site. Show that pedestrian areas will be kept flood free for up to a 10-year event. (DS 2-02.2.1.A.16) 4) Show existing contours or spot elevations and provide basis of elevation. (DS 2-02.2.1.A.23) Revise the Site Plan to address all of these comments and resubmit two copies for review. Include a letter explaining how each comment has been addressed. A grading permit is required for this project. Submit a complete grading permit application including a grading plan showing the extent of the proposed work. If you have any questions or if you would like to set up a meeting, please call me at (520) 791-5550 ext. 1161 or email me at loren.makus@tucsonaz.gov. Loren Makus Senior Engineering Associate Engineering Division Development Services |
| 05/06/2004 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Jim Fields PO Box 556 Sonoita, AZ 85637 FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: T04CM00675 A-Access Self Storage 4070 E. 29th Street Site Plan Review (2nd review) TRANSMITTAL: May 6, 2004 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Note 7 indicates the existing /proposed use on the southern portion of the lot (to the south of the 6-foot chain link fence) "is vacant and will remain so". However, upon site inspection it is found that this area of the site is currently being used for vehicle storage. Please clarify. The site plan shall not be approved until the southern portion of the site is vacated. Also, label any other structures/uses within this portion of the site such as the small building and monopole (cellular tower?) located within the easement. DS 2-02.2.1.A.31 2. In the van accessible handicap parking space detail label the maximum slope of the aisle and ramps provided. ANS/IBC If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 05/06/2004 | PETER MCLAUGHLIN | HANDICAP-SITE | REVIEW | Approved | |
| 05/10/2004 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 05/10/2004 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/12/2004 | ANGIE SHOFFSTALL | OUT TO CUSTOMER | Completed |