Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM00675
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/24/2004 | Jim Egan | FIRE | REVIEW | Approved | |
| 03/29/2004 | Peter McLaughlin | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Jim Fields PO Box 556 Sonoita, AZ 85637 FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: T04CM00675 A-Access Self Storage 4070 E. 29th Street Site Plan Review (1st review) TRANSMITTAL: March 30, 2004 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This project is being reviewed as a greater than 25 % expansion. Full code compliance is required. DS 2-02 2. Label the future curb and sidewalk locations, if different from existing locations, on the site plan per the MS&R plan. DS 2-02.2.1.A.10 & .21 3. Continuous pedestrian circulation must provide a connection between the buildings and the right-of-way along 29th Street. Revise to show pedestrian connection. Pedestrian sidewalks must be a minimum of 4 feet in width. The parking detail shows a sidewalk of only 3 feet in front of the handicap parking space. Revise to show a 4-foot sidewalk. DS 2-08.4.1.A DS 2-02.2.1.A.12 4. Provide a more distinct separation between the site plan drawing and location map so adjacent zoning is clearly identified with location map only. Identify the site zoning as C-2 in the notes. DS 2-02.2.2.A.6 5. For microfilming/archiving purposes, all text must be a minimum of 12 (0.12") point in size. Please revise the lettering in the survey maps to meet this minimum standard. DS 2-05.2.1.D.2 6. Provide a fully dimensioned bicycle parking detail demonstrating that it meets the minimum dimensional requirements of DS 2-09, including a 6-foot length for bicycles and a 5-foot maneuverability area. DS 2-02.2.1A.9 7. Indicate the existing /proposed use on the southern portion of the site (to the south of the 6-foot chain link fence). 2002 aerial photos show vehicles being stored in this area. Because this is a full code compliance review, the entire site must meet code. Revise site plan to indicate the use of this part of the site and demonstrate compliance with LUC and Development Standards. DS 2-02.2.1.A.31 8. Remove the word "perimeter" from the label for the 6-foot chain link fence as this fence is not on the perimeter of the site. 9. Dimension street setbacks from property line along Irving Avenue to bldgs. 4 and 5. They do not appear to meet side street established neighborhood setback requirement of 10 feet from property line. Provide a copy of last approved site plan for the self-storage facility. DS 2-02.2.1.A.7 10. The site is within the Airport Environs Zone Airport Hazard District. Add a note to indicate that the elevation above median sea level (MSL) of the NW end of the NW/SE runway at Davis-Monthan AFB is 2,590 feet. Add the elevation above mean sea level of the site to the plan and state the max height of the proposed building, which may not to exceed 2,740 feet (150 feet above the elevation of the northwest end of the east end of runway 21) above MSL. LUC 2.8.5.7.A.1 11. LUC 3.3.7.2.C.4 requires that the minimum width of a one-way PAAL within a storage development be a minimum of twenty (20) feet in width with a four (4) foot wide pedestrian refuge area delineated on one (1) side of the PAAL. As redlined on the plan, please remove the pedestrian refuge from one side of the proposed one-way PAALs. LUC 3.3.7.2.C.4 12. Add the development designator "31" for the personal storage use and detail the restrictions which the use is subject to in the C-2 zone. The personal storage use is subject to LUC Sec. 3.5.10.3.C and .F. Demonstrate compliance with these restrictions by labeling the color and materials of the exterior façades of the buildings that are visible from the street frontage and residential properties. Also indicate that any walls or doors visible from adjacent street are to be surfaced with a non-reflective material as required. LUC 2.5.4.2.H.2 13. Add a general note stating that the plan meets the criteria of LUC 3.8.3, Major Streets and Routes Setback Zone. 14. Show on the plan how the one-way direction of traffic flow is to be indicated on site, either with painted directional arrows on the pavement, or with signage, or both. 15. If easements exist on the site, please show their location, type, width and provide recordation information. DS 2-02.2.1.A.20 16. The location, type, size and height of any existing or proposed free-standing signage (including billboards) must be shown on the drawing. DS 2-02.2.1.A.13 17. Between any building and PAAL a minimum 5-foot pedestrian refuge, including a 4-foot sidewalk is required. Dimension the existing pedestrian between the PAAL and existing office building. DS 3-05.2.2.B.1 18. For the single handicap parking space provided a van accessible aisle with 8-foot width is required. Remove the 5-foot dimension fron the parking detail and revise drawing to demonstrate compliance by showing an 8-foot h/c aisle adjacent to the parking space. ANS/IBC 19. All applicable changes must also be made on landscape plan and NPPO plan. If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 03/30/2004 | PETER MCLAUGHLIN | HANDICAP-SITE | REVIEW | Denied | Seein zoning review comments. |
| 03/31/2004 | Loren Makus | ENGINEERING | REVIEW | Denied | DATE: April 1, 2004 TO: Jim Fields Architect, Inc. SUBJECT: A-Access Self Storage Site Plan REVIEWER: Loren Makus ACTIVITY NUMBER: T04CM00675 SUMMARY: The Site Plan was reviewed by Development Services Department, Engineering Division on April 1, 2004. The site plan was not approved. Please address the following comments. Site Plan Comments: 1) Show all existing structures including any structures on "Lot B" "(Development Standard (DS) 2-02.2.1.A.8) 2) Provide estimated cut and fill quantities. (DS 2-02.2.1.A.17) 3) Show proposed drainage patterns including roof drainage and show finish grades throughout the site. Show that pedestrian areas will be kept flood free for up to a 10-year event. (DS 2-02.2.1.A.16) 4) Show existing contours or spot elevations and provide basis of elevation. (DS 2-02.2.1.A.23) Revise the Site Plan to address all of these comments and resubmit two copies for review. Include a letter explaining how each comment has been addressed. When the site plan is approved, submit application for a grading permit, if it is determined to be necessary. Loren Makus Senior Engineering Associate Engineering Division Development Services |
| 04/19/2004 | Joseph Linville | LANDSCAPE | REVIEW | Denied | 1) Indicate both the proper and common name of each type of plant material DS 2-07.2.2.A.d 2) Provide a 30"continuous screen along 29th St. per LUC Table 3.7.2-I. 3) Provide a 5' continuous screen along Irving Ave. per LUC Table 3.7.2-1 4) Screens may be located in the landscape border if the criteria indicated in LUC3.7.3.2 are met. 5) Any screen higher than thirty (30) inches must be located outside of the sight visibility triangle per LUC 3.7.3.4 6) Refer to LUC 2.8.3.5. Temporary use of MS&R right of way is proposed to meet landscape and screening requirements. 7) Street landscape borders shall be a minimum of ten (10) feet wide as measured from the street property line, and located entirely on site per LUC 3.7.2.4. Revise landscape borders on 29th and Irving 8) Included Length and width of landscape borders per DS 2-07.2.2.A.2.f 9) Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.A.2.g 10) Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4 11) 20% of shrubs in landscape border are required to be 5 gallon size DS 2-06.3.5.F 12) Landscape plan shall include irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. 13) The landscape plan shall indicate use of all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area per LUC 3.7.4.3.B 14) A 6' screen for refuse storage is required for adjacent properties LUC Table 3.7.2-I 14) All disturbed, areas shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7 |
| 04/20/2004 | ANDREW CONNOR | NPPO | REVIEW | Denied | Indicate both the proper and common name of each type of plant material DS 2-07.2.2.A.d |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/22/2004 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 04/21/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |