Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T04CM00634
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/25/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Submit last stamped and approved site and landscape plans to continue review. Include calculation for new vehicle use area(s). 2. On sites where the gross floor area of the existing building(s) is ten thousand (10,000) square feet or less, expansions in square footage of land area, floor area, lot coverage, or vehicular use area as follows. If the expansion is less than fifty (50) percent, the requirements of this Division apply only to the proposed expansion. Existing development on the site is subject to the zoning regulations in effect at the time the existing development received zoning approval. If the expansion is fifty (50) percent or greater or if expansions as of February 15, 1991, cumulatively result in a fifty (50) percent or greater expansion in land area, floor area, lot coverage, or vehicular use area, the requirements of this Division apply to the entire site. 3. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a 4. Submit NPPO plan or application for exception per 2-15.0 5. Additional comments may apply |
| 07/26/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or application for exception per 2-15.0 |
| 08/17/2005 | DAVID RIVERA | ZONING HC SITE | REVIEW | Approved | |
| 08/17/2005 | DAVID RIVERA | ZONING | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES DEPARTMENT ZONING REVIEW SECTION DATE: August 17, 2005 ACTIVITY NUMBER: T04CM00634 PROJECT NAME: Sonoran Art Foundation PROJECT ADDRESS: 633 West 18th Street PROJECT REVIEWER: Patricia Gehlen/David Rivera The following items must be revised on or added to the site plan. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed: 1. The parking calculation has been done incorrectly. The calculation must be revised to include parking for the overall building square footage at a ratio of one space per 200 square feet of gross floor area or at a ratio of one space per 250 square feet of of office area plus one space per one hundred square feet of classroom area. Whichever of the two calculations is greater is the one the must be used. A dimensioned floor plan may be required in order to verify the parking requirements. Previous Comment: The parking calculations must be revised. Please refer to LUC 3.3.4 for the minimum parking required for an instructional school. A breakdown of the use by floor area will be required to determine the number of vehicle spaces required (DS 2-02.2.2.A.4), |
| 08/24/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: August 24, 2005 ACTIVITY NUMBER: T04CM00634 PROJECT NAME: Sonoran Art Foundation PROJECT ADDRESS: 633West 18th Street PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. Depict the limits of the 100-year water surface elevations onsite, and provide a note that the site lies within the 100-year regulatory floodplain. (DS 2-02.2.1 A 15). 2. Provide the proposed building's lowest recommended (finished) floor elevation found in the hydrology report. (DS 2-02.2.1 A16). 3. Provide estimated cut/fill quantities (DS 2-02.2.1A17). 4. Indicate the datum used for the FFE. DS 2-02.2.1.A.23. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/25/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 08/25/2005 | SUE REEVES | REJECT SHELF | Completed |