Permit Number: T04CM00634
Parcel: 11623155D

Address:
633 W 18TH ST

Review Status: Completed

Review Details: SITE

Permit Number - T04CM00634
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/26/2004 JIM EGAN FIRE REVIEW Approved
04/08/2004 Doug Williams ENGINEERING REVIEW Denied SUBJECT: Site Review - 633 W. 18th Street
REVIEWER: Doug Williams
DATE: 8 April 2004
ACTIVITY NUMBERS: T04CM00634/T04OT00625

SUMMARY: Engineering Division has reviewed the Hydrology Report, Site Plan and Floodplain Use Permit application received on 26 March 2004. Approval of the site plan is not recommended at this time. The hydrology report is acceptable for floodplain permit issuance purposes, however the permit may not be issued prior to site approval. The following comments are offered:

SITE PLAN
1. Provide lot dimensions and bearings (Development Standard -DS- 2-02.2.1 A 5).
2. Depict sight visibility triangles for the DRIVE/PAAL intersecting a local street (18th Street) (DS 2-02.2.1 A 10 & 3-01.5.0).
3. Dimension existing ingress/egress, PAAL, and driveway width(s) (DS 2-02.2.1A 11).
4. Depict loading space maneuvering area (DS 2-02.2.1 A 14).
5. Depict the limits of the 100-year water surface elevations onsite, and provide a note that the site lies within the 100-year regulatory floodplain (DS 2-02.2.1 A 15).
6. Provide the proposed building's lowest recommended (finished) floor elevation and finished site grades on the plan (DS 2-02.2.1 A16).
7. Provide estimated cut/fill quantities (DS 2-02.2.1 A17).
8. Depict the 18th Street half right of way (DS 2-02.2.1A19).
9. Provide recording information for the lease area, on the plan (DS 2-02.2.1A 20).
10. Dimension and label from street monument line(s) to existing curb and sidewalk, (or edge of pavement) and utility locations (DS 2-02.2.1 A 21).
11. Identify and label the adjacent drainageway (DS 2-02.2.1 A 22).
12. Depict/provide existing topographic contours at intervals not exceeding 2 feet and/or spot elevations as pertinent and Bench mark based on City of Tucson Datum, including City Field Book and page number (DS 2-02.2.1 A23).
13. Depict the existing refuse container access, fully dimensioned (DS 2-02.2.1 A32).
14. Demonstrate water harvesting to the maximum extent reasonably possible, in accordance with the City of Tucson Land Use Code - Section 3.7.4.3 B.
15. Depict roof drainage arrows with downspout locations indicated, and depict/label sidewalk scuppers for conveyance under sidewalk areas at each location for conveyance of 10-year flows at a minimum (DS 2-08.4.1 E & 3-01.4.4 F).
If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Doug Williams
Sr. Engineering Associate
Engineering Division
Development Services Department
04/09/2004 Patricia Gehlen ZONING REVIEW Denied CITY OF TUCSON DEVELOPMENT SERVICES DEPARTMENT
ZONING REVIEW SECTION

DATE: April 20, 2004
ACTIVITY NUMBER: T04CM00634
PROJECT NAME: Sonoran Art Foundation
PROJECT ADDRESS: 633 West 18th Street
PROJECT REVIEWER: Patricia Gehlen

The following items must be revised on or added to the site plan. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed:

1. Per the City Attorney's office, a land lease is the same as a lot split. Please provide copies of the city approved lot split documents with the resubmittal of these plans,
2. Add the address to the site plan (DS 2-02.2.1.A.3),
3. The location map does not make sense. Please add a north arrow for clarification (DS 2-02.2.1.A.4),
4. Revise the existing use to "Instructional School" (Trade School is not a use in the Land Use Code) (DS 2-02.2.1.A.31),
5. The parking calculations must be revised. Please refer to LUC 3.3.4 for the minimum parking required for an instructional school. A breakdown of the use by floor area will be required to determine the number of vehicle spaces required (DS 2-02.2.2.A.4),
6. If the bicycle parking is proposed (not existing), the location must be shown on the site plan, fully dimensioned. Please refer to DS 2-09 (DS 2-02.2.1.A.9),
7. If applicable, the location, width, type, and recordation information for all existing and proposed easements must be added to the site plan (DS 2-02.2.1.A.20),
8. Add all adjacent zoning to the site plan (DS 2-02.2.1.A.28),
9. Revise the "coverage" calculation to read "floor area ratio". The floor area ratio is Gross Floor Area divided by lot area. It appears to be 10%. Revise as required (DS 2-02.2.2.A.3),
10. The notes indicate a handi-cap parking space is provided on site but can not be located. Revise the site plan as required.
04/20/2004 PATRICIA GEHLEN HANDICAP-SITE REVIEW Denied Zoning
4/20/2004
See zoning comments
04/20/2004 Joseph Linville LANDSCAPE REVIEW Needs Review
04/20/2004 JOE LINVILLE NPPO REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
04/21/2004 TAMI ACHONG OUT TO CUSTOMER Completed
04/21/2004 ANGIE SHOFFSTALL REJECT SHELF Completed