Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T04CM00554
Parcel: 117143780

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM00554
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/11/2004 MELISSA POULIN WWM REVIEW Approved
03/03/2004 David Witt BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T04CM00554

3/4/04 715 S. 11TH AVE. #1, #2

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.
2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

SITE PLAN:

1. INDICATE THE LOCATION OF GAS, WATER, ELECTRIC AND SEWER OR SEPTIC LINE ON THE PROPERTY, AND
WHERE THEY ENTER THE BUILDING. PROVIDE THE LOCATION OF YOUR WATER METER AND SEPTIC SYSTEM
IF IT EXISTS.

2. PROVIDE DISTANCES TO PROPERTY LINES.

3. CALL FRANK PODGORSKI @ 791-5550 EXT. 1145 REGARDING THE A/C UNITS THROUGH THE WALL.

FLOOR PLANS:

1. LABEL ALL ROOMS AND SPACES. SHOW ALL DOORS.

2. DIMENSION THE LOCATIONS OF THE NEW INTERIOR PARTITIONS.

3. NOTE THAT BATHTUB AND SHOWER ENCLOSURES SHALL BE FINISHED PER p2710 WITH CERAMIC TILE, OR A
LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE DRAIN PER R702.4 AND R307.2

4. NOTE AND SPECIFY THAT SHOWER ENCLOSURES SHALL HAVE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES AND SHALL BE CAPABLE OF ENCOMPASSING A MINIMUM 30" CIRCLE PER UPC SEC. 410.0. ALL GLASS ENCLOSURES SHALL BE TEMPERED.

5. SHOW THAT EACH WATER CLOSET IS LOCATED IN A CLEAR SPACE NOT LESS THAN 30" WIDE AND HAS A
CLEAR SPACE IN FRONT OF NOT LESS THAN 24" PER R307.2 (FIGURE).










ELEVATIONS:

1. INDICATE ALL MATERIALS USED; STUCCO, CONCRETE BLOCK, GLASS BLOCK, ROOFING SYSTEMS, SIDING,
VENEERS, ETC.

2. NOTE AND SPECIFY ALL ROOF SLOPES APPROPRIATE TO MATERIAL (SEE R905).

3. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL
VENTS NEEDED TO COMPLY.

4. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4.

SECTIONS - DETAILS - MISC. NOTES:

1. PROVIDE THE THICKNESS OF THE ANGLE IRONS TO BE USED AS LINTILS OVER THE A/C UNITS.

2. PROVIDE A LISTED SYSTEM TO ACCOMMODATE THE PLUMBING PENETRATIONS OF THE ONE HOUR COMMON WALL.

3. PROVIDE A CROSS SECTION OF A TYPICAL NEW INTERIOR PARTITION AND SPEC THE CONNECTION TO THE ADOBE.

PLUMBING PLANS:

1. NOTE AND SPECIFY ALL PIPING MATERIALS FOR THE DWV SYSTEM.

2. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH

3. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS
AND SHOWERHEADS 3 GALLONS PER MINUTE.

4. PROVIDE A V.T.R. FOR THE CLOTHES WASHER FOR UNIT 2 .

5. PLUMBING NOTE 1 ; TYPE M COPPER IS APPROVED FOR ABOVE FLOOR USE. PLEASE ADD THIS NOTE TO THE SPECs. TYPE L IS APPROVED FOR UNDER FLOOR USE.

6. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE AT WATER HEATERS.

7. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL
VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE.

8. EACH PLUMBING TRAP REQUIRES A VENT BUT UNIT 2's CLOTHES WASHER AND SHOWER TRAPS APPEAR TO BE ON ONE TRAP ARM. PLEASE RECTIFY.

9. PLEASE NOTE P.V.C. WATER LINES ARE APPROVED ONLY FOR COLD WATER OUTSIDE THE BUILDING.

MECHANICAL PLANS:

1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC.

2. PROVIDE THE SUPPLY AIR TRUNK SIZE AT UNIT 1's GAS PACK PER M1603 .

3. SHOW EXHAUST FAN LOCATIONS FOR BATHROOMS, WATER CLOSET COMPARTMENTS AND LAUNDRY ROOMS
IN LIEU OF OPERABLE WINDOWS, PER R303.3

4. GAS APPLIANCES SHALL COMPLY WITH THE U.P.C. COMBUSTION AIR REQUIREMENTS. DETAIL HOW.

5. PROVIDE AND SIZE THE RETURN AIR FOR UNIT 1 PER M1602 .

ELECTRICAL PLANS:

1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC.

2. ELECTRIC NOTE 2 ; FOR 6" BURIAL BENEATH A BRICK FLOOR, TABLE E 3703.1 REQUIRES EITHER G.F.C.I. PROTECTION OR I.M.C. OR RIGID CONDUIT.

3. RECEPTACLE OUTLETS SHALL BE PROVIDED AT EACH KITCHEN COUNTER SPACE WIDER THAN 12", AND
SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24" FROM A RECEPTACLE
OUTLET, PER E3801.4.1 SEE UNIT 2's TOP BETWEEN THE SINK AND THE REFRIGERATOR . IS THERE A TOP BETWEEN THERANGE AND THE SINK?

4. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11.

5. PROVIDE RECEPTACLES WITHIN 6' OF UNIT 2's LIVING ROOM DOOR TO THE KITCHEN

6. PROVIDE A RECEPTACLE BETWEEN UNIT 2's BEDROOM DOOR AND LIVINGROOM DOOR.

7. SHOW LOCATIONS OF SMOKE DETECTORS PER R317. NOTE THAT ALL SMOKE DETECTORS MUST BE
INTERCONNECTED WITH A POWER SOURCE FROM THE BUILDING WIRING, AND SHALL BE EQUIPPED WITH
BATTERY BACKUP. PLEASE ADD A SMOKE DETECTOR IN THE AREAS IMMEDIATELY OUTSIDE THE BEDROOMS.


IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110


NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES.

ADDITIONAL PLAN CHECK COMMENTS
A LICENSED GENERAL CONTRACTOR IS REQUIRED ON THIS PROJECT PER THE REGISTRAR OF CONTRACTORS.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/09/2004 TAMI ACHONG OUT TO CUSTOMER Completed
03/09/2004 SUE REEVES REJECT SHELF Completed