Permit Number: T04CM00358
Parcel: 115061580

Address:
1893 N 11TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T04CM00358
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2004 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: January 30, 2004
ACTIVITY NUMBER: T04CM00358
PROJECT NAME: Top Gem Minerals
PROJECT ADDRESS: 1820 North Oracle Road
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. Sidewalks must be flood free for up to the 10-yr. event. Add a note on the plan, "All roof down spouts on all structures must be routed under any adjacent sidewalk." DS 2-08.4.1.E

2. Stormwater must be accepted and released from developments essentially at the same locations, and with the same magnitudes, as encountered under natural or existing conditions. The natural contours depict the direction of flow toward the southeast. The plan shows drainage from the PAAL going towards the east and the west. Include a drainage statement addressing the historic and proposed conditions of the site. SMDDFM 12.5

3. Alley access will not be allowed. Revise plan accordingly.

4. Include finish grades on the plan. DS 2-02.2.1.A.16.

5. Label and dimension from street centerline to existing and proposed curbs and sidewalks. Revise plan as necessary. DS 2-02.2.1.A.21.

6. Include on plan the sight visibility triangles (SVT) for Plata Street, 11th Avenue and for the alley to Plata Street. For a local to a local street the near side SVT length is 180' and the far side is 110'. For an alley to a local street the near side SVT length is 185' and the far side length is 110'. Revise plan to show the SVTs. DS 2-02.2.1.A.10.

7. The trash enclosure is not accessible. The maximum back-up distance for the collection vehicle is forty (40) feet. Revise plan accordingly or contact John Clark (Environmental Services 791-3175 ext. 1136) for written approval of the current position of the trash enclosure. DS 6-01.
02/23/2004 David Rivera ZONING REVIEW Denied FROM: David Rivera
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT: T04CM00358
SW Corner of 11th Avenue and Plata Street
Commercial Storage
Site Plan

Transmittal date: 1st Review February 26, 2004

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The above activity number has been assigned to this project but to an incorrect address. An address certificate and for the parcel in review must be attained before zoning will approve the site plan. Add to the plan the correct address assigned by Pima County Addressing. Insure that the COT Site Review Record card has been revised with the correct address and that the correct address has been entered into the computer by the CSR's before re-submitting the site plan for a second review or at the time that the site plan will be submitted for the second review. DS 2-02.2.1.A

2. Submit copies of the building elevations with height dimensions in order to verify the proposed street building setbacks. The building setback must be dimensioned from design grade to the top of parapet, top of plate, or top of gable. DS 2-02.2.1.A.7

3. Please verify what specific use is proposed. Under the parking calculation the proposed use is noted as Commercial Storage but the parking ratio used is for a Wholesale use. Please clarify the specific use and revise the parking calculations appropriately. If the specific use is Commercial Storage the number of vehicle parking spaces required will be less than indicated but will be acceptable as excess parking. DS 2-02.2.1.A.8

4. The bicycle parking calculations must be revised appropriately. The bicycle parking calculation indicates that class one parking spaces will be provided yet the detail drawing is for class two spaces. In addition the detail drawing does not depict the actual facility as proposed on the site. Please revise the detail drawing, dimension as required, and state what type of surfacing is proposed. The type of lighting proposed for the facility must be noted and because the location of the facility is not visible from the street frontage signage directing the cyclist to the facility must be provided. Show and label the bicycle directional signage. DS 2-02.2.1.A.9

5. Please demonstrate maneuverability into and out of the loading space. It does not appear that a 55-foot long tractor-trailer would be able to maneuver in and out of the loading space in its present location. Also please add a note stating the number of loading spaces required and provided. DS 2-02.2.1.A.14

6. Under the General Site Information add as a note, the existing use of the site. DS 2-02.2.1.A.31

7. See Engineering comments related to the refuse container location. DS 2-02.2.1.A.32

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and landscape plan and requested documents
03/01/2004 DAVID RIVERA HANDICAP-SITE REVIEW Denied Show accessible ramp crosswalk and concrete sidewalk connection. Dimension the ramp and label the slope. See additional zoning comments
03/01/2004 JIM EGAN FIRE REVIEW Denied 1. Submit complete code review checklist.(M, F-1 & S-1 ocupancies exceeding 12000 sq. ft. require fire sprinklers.)

2. Indicate location of existing fire hydrant on plan.
03/04/2004 Andrew Connor NPPO REVIEW Denied 1) Include the correct address and the activity number on the NPP application.

2) Include documentation which substantiates that there are no protected plants on site. DS 2-15.2.0 The aerial photo received shows some vegetation.

3) Provide a copy of the plan # T03BU00550 if it included removal of vegetation.
03/04/2004 Andrew Connor LANDSCAPE REVIEW Denied 1) Add the correct address and legal description to the landscape plan. DS 2-07.2.2

2) Revise the landscape plan to clarify what type of screen is proposed along 11th Avenue. DS 2-07.2.2.A.3

3) The refuse storage area screening is required to be 6' high. Add call out or note to clarify. LUC Table 3.7.2-I

4) Keynote 24 is listed, but not shown on the plans.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/11/2004 TAMI ACHONG OUT TO CUSTOMER Completed
03/05/2004 ANGIE SHOFFSTALL REJECT SHELF Completed