Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T04CM00328
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2004 | BLANCA ESPINO | ENGINEERING | REVIEW | Approved | |
| 11/22/2004 | Robert Suba | ELECTRICAL-COMMERCIAL | REVIEW | Denied | 1.Please increase min. font size to 10 on all comments,cut sheets,notes etc. so that when plans are reproduced into micro-fish (film) they will be clear and ledgeable. |
| 12/08/2004 | Christy Foreman | BUILDING-COMMERCIAL | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES STRUCTURAL REVIEW COMMENTS DATE: 12/09/04 ACTIVITY NUMBER: TO4CM00328 PROJECT NAME: STEEL CANOPY PROJECT ADDRESS: 231 W. ALTURAS ST. ARCHITECT / ENGINEER: JOHN JAMES GLANCY & MUHAMMAD ALMAHAYNI PROJECT REVIEWER: CHRISTY FOREMAN PHONE: 791-5550 X1108 EMAIL: CFOREMA1@CI.TUCSON.AZ.US TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CFOREMA1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS. 1) PROVIDE A COMPLETED CODE ANALYSIS DATA SHEET FOR COMBINATION OF LOTS. CHAPT.3 - 303-312 OCCUPANCIES, 302.3.1 NONSEPERATED USES EACH PORTION OF THE BUILDING SHALL BE INDIVIDUALLY CLASSIFIED AS TO USE. THE REQUIRED TYPE OF CONSTRUCTION FOR THE BUILDING SHALL BE DETERMINED BY APPLYING THE HEIGHT AND AREA LIMITATIONS FOR EACH OF THE APPLICABLE OCCUPANCIES TO THE ENTIRE BUILDING. THE MOST RESTRICTIVE TYPE OF CONSTRUCTION SO DETERMINED SHALL APPLY TO ENTIRE BUILDING. ALL OTHER CODE REQUIREMENTS SHALL APPLY TO EACH PORTION OF THE BUILDINGBASED ON THE USE OF THAT SPACE, EXCEPT THAT THE MOST RESTRICTIVE APPLICABLE PROVISIONS OF SECTION 403 AND CHAPTER 9 SHALL APPLY TO THESE NONSEPERATED USES., 302.3.3 - EACH PORTION OF A BUILDING SHALL BE INDIVIDUALLY CLASSIFIED AS TO USE AND SHALL BE COMPLETELY SEPERATED FROM ADJACENT AREAS BY FIRE BARRIER WALLS OR HORIZONATAL ASSEMBLIES OR BOTH HAVING A FIRE RESISTANCE RATING DETERMINED IN ACCORDANCE WITH TABLE 302.3.3. CHAPT. 5 GENERAL BLDG. HEIGHTS AND AREAS - TABLE 03 ALLOWABLE HEIGHT AND BUILDING AREAS, 503.1.3 BUILDINGS ON THE SAME LOT. TWO OR MORE BUILDINGS ON THE SAME LOT SHALL BE REGULATED AS SEPARATE BUILDINGS OR SHALL BE CONSIDERED AS PORTIONS OF ONE BUILDING IF THE HEIGHT OF EACH BUILDING AND THE AGGREGATE AREA OF BUILDINGS ARE WITHIN THE LIMITATIONS OF TABLE 503 AS MODIFIED BY SECTIONS 504 & 506. CHAPT. 6 TYPES OF CONSTRUCTION - TABLE 602 FIRE RESISTIVE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPERATION DISTANCE. CHAPT. 7 -704.3 BUILDINGS ON THE SAME PROPERTY SHALL BE ASSUMED TO HAVE A PROPERTY LINE BETWEEN THEM. 2) PROVIDE A SITE PLAN THAT REFLECTS THE COMBINATION OF LOTS AND ADDRESSES. CLARIFY ON SITE PLAN THAT IBC CHAPT. 11 REQUIREMENTS HAVE BEEN MET. SUCH AS PUBLIC WAY, ROUTE OF TRAVEL, AND PARKING. 3) WALL PANELS? DETAILS NOTE WALL PANELS. ELEVATIONS DO NOT SHOW WALL PANELS. PLEASE CLARIFY. 4) SPECIAL INSPECTION REQUIRED FOR FIELD WELDS BEFORE PERMITS CAN BE ISSUED. |
| 12/15/2004 | DAVID RIVERA | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/03/2005 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 01/03/2005 | SUE REEVES | REJECT SHELF | Completed |