Permit Number: T04CM00212
Parcel: 126210830

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM00212
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/18/2004 Neil Saunders BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project T04CM00212

Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

General Requirements

1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned.
2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes.

Structural Plans

1. Provide lintels for veneer at openings.
2. Provide a complete analysis for line 2 of lateral analysis (i.e. tube steel design, detail 207, header H2)
3. Special inspection will be required for welding. Form is attached.
4. Provide a landing at east exterior door per R312.
5. If underside of carport is to be sheathed then provide attic ventilation per R806.2

Electrical Plan

1. Provide a switch operated light outside shop doors per E3803.3

Plumbing Plan

1. Provide note: All plumbing shall comply with 1994 UPC and State amendments.
03/22/2004 MELISSA POULIN WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/26/2004 LISA LESNY OUT TO CUSTOMER Completed
03/22/2004 SUE REEVES REJECT SHELF Completed