Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 3RD
Permit Number - T04CM00105
Review Name: REVISION - - 3RD
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/17/2008 | GERRY KOZIOL | WWM | REVIEW | Passed | |
| 11/25/2008 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T04CM00105 12/2/08 402 N. DESERT SV. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. STRUCTURAL PLANS: 1. ROOF FRAMING / 5 ; JUSTIFY THE USE OF SIMPSON SD8X1.25 WOOD SCREWS ON A MASONRY BUILDING AT THE B48 SUPPORTING THEBEAMS BETWEEN THE WORKSHOP AND THE HOUSE.. ELEVATIONS: 1. IS THE 8'X4' PORCH TO REMAIN AS SHOWN IN THE SOUTH ELEVATION? IT'S Xed OUT ELSEWHERE. SECTIONS - DETAILS - MISC. NOTES: 1. 5 / 4 ; PLEASE DIMENSION THE FIREPLACE FOOTING AND THE HEARTH EXTENSION. FIGURE R1001.1 2. 5 / 4 ; PLEASE DIMENSION THE FIREBOX OPENING AND THE FLUE SIZE. FIGURE R1001.1 3. 2 / 6 ; THE SIMPSON "CB" SERIES POST BASES DON'T RAISE THE END GRAIN OF THE POST 1" OFF THE FLOOR. WILL THE FLOOR BE 6" ABOVE THE ADJACENT GRADE OR THE POST BE REDWOOD OR EQUAL. R319.1.4 4. 6 / 4 ; PLEASE DIMENSION THE MAXIMUM HEIGHT OF THE WALL IN THE DETAIL. 5. A2 / 3 ; JUSTIFY THE R-19 INSULATION IN THE ROOF. IRC N1102.1 6. 2 / 5 ; WHY DO THE RAFTERS NEED TO BE NOTCHED? HOW MUCH? CAN THE NOTCH BE AVOIDED? IT'S ON A PONY WALL.ARE YOU BUILDING THE PONY WALL TO TALL? 7. 1 / 5 ; PLEASE CHANGE THE GRADE OF THE 8X8 TO "NO. 1 AND BETTER" INSTEAD OF " NO. 1 OR BETTER". PLUMBING PLANS: 1. SOUTHWEST GAS CHANGED THE VALUE OF A CUBIC FOOT OF GAS FROM 1200 BTUH TO 1000 BTUH. PLEASE PROVIDE THE DEVELOPED LENGTH OF THE RE-ROUTED GAS LINE AND THE GAS APPLIANCES WITH THEIR INPUT RATES IN ORDER TO CHECK THE DIAMETER OF THE NEW GAS SERVICE LINE. ELECTRICAL PLANS: 1. PLEASE PROVIDE A NOTE THAT THE ELECTRICAL SERVICE PANEL REQUIRES A WORKING AREA NOT LESS THAN 30" WIDE BY 36" DEEP. E3305.1 2. A RECEPTACLE IS REQUIRED FOR THE FRONT YARD. E3801.7 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/03/2008 | CPIERCE1 | OUT TO CUSTOMER | Completed |