Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T04CM00080
Parcel: 133552300

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T04CM00080
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/15/2004 JIM EGAN FIRE REVIEW Approved
01/15/2004 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
01/15/2004 Robert Sherry PLUMBING-COMMERCIAL REVIEW Denied 1. Provide equipment data for water heater. Reference Section 103.2.3, UPC 1994.
2. Confirm that suspended water heater complies with the access requirements of section 511.0, UPC 1994 with AZ State amendments.
3. Provide detail of water heater installation, including excess pressure relief, expansion tank, and valves. Reference Section 103.2.3, UPC 1994.
4. If the specified water heater is not supplied with integral heat traps, provide heat traps on the supply and discharge piping along with ½" insulation on the first eight feet of supply and discharge piping. Reference Section 704.4, IECC 1998.
5. Provide calculations showing water supply piping is sized in accordance with Section 610.4, UPC 1994.
6. Provide upper terminal cleanouts on horizontal drainage pipe. Reference Section 707.4, UPC 1994.
7. Show that the connection of the new vent to an existing 1-1/2" vent will comply with the requirements of Table 7-5, UPC 1994.
01/15/2004 ROBERT SHERRY WATER REVIEW Approved
01/21/2004 Martin Haeberle BUILDING-COMMERCIAL REVIEW Approved
01/26/2004 Linda Buczynski ELECTRICAL-COMMERCIAL REVIEW Approved
01/27/2004 GERRY KOZIOL WWM REVIEW Denied Needs holds harmless letter. Public sewer not released as yet.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/29/2004 LISA LESNY OUT TO CUSTOMER Completed
01/27/2004 ANGIE SHOFFSTALL REJECT SHELF Completed