Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T04CM00079
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/01/2004 | Andrew Connor | NPPO | REVIEW | Approved | Exception |
| 07/01/2004 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | After site plan (including landscape plan) approval and prior to permit issuance an executed covenant for recordation stating the responsibility of the property owner, successor, or assignee as to the removal of improvements and compliance with the LUC at no cost to the City is required per LUC 2.8.3.5.F to comply with MS&R regulations. Copies of an acceptable document are available at the zoning review counter or online at http://www.ci.tucson.az.us/dsd/E-Services/Applications___Forms/Major_Streets_Covenant.pdf. Include copies of recorded covenant to continue review. |
| 07/23/2004 | Daniel Castro | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next CODE SECTION/ submittal, which states how all Zoning Review Section comments DEVELOPMENT regarding the Land Use Code and Development Standards were STANDARD addressed. 1. Copy of recorded Lot combination covenant and MS&R covenant to be provided prior to site plan approval. 2. a) A total of 36 vehicle parking spaces are required for the site prior to future right-of-way dedication. A total of 28 vehicle parking spaces are to be provided, which results in a deficiency of eight (8) vehicle parking spaces. b) A total of 31 vehicle parking spaces are required for the site after right-of-way dedication. The "future site plan" provides a total of 21 vehicle parking spaces, which results in a deficiency of 12 vehicle parking spaces. 3. A five (5) foot wide pedestrian refuge area with a minimum four (4) foot wide concrete sidewalk is required along the entire south and east sides of building 2. There are portions of this area, which do not comply with the minimum width requirements along the entire path. (D.S. 2-08.4.1.B) (D.S. 3-05.2.2.B.1) 4. Since a Board of Adjustment Variance will be applied for, please list as a general note, the case number, date of approval, variances granted, and any conditions imposed. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 07/23/2004 | DAN CASTRO | HANDICAP-SITE | REVIEW | Denied | Refer to Zoning Review comments. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/27/2004 | BETH GRANT | OUT TO CUSTOMER | Completed |
| 07/27/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |