| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/25/2005 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | assignment per JPV |
| 02/25/2005 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal. 2. The Drainage Report has been reviewed and approved as part of the Floodplain Use Permit review. 3. Sight Visibility Triangles are clear lines of sight will be maintained along all streets and driveways to assure the safety of motorists and pedestrians. D.S.3-01.5.1 Lines of sight will not be obscured between thirty (30) inches and six (6) feet through a triangular area adjacent to a driveway, a PAAL, an alley, or a street, where such access ways intersect with another street in a T-configuration. D.S.3-01.5.1.A.1 4. The proposed retaining wall exceeds the required height for a Sight Visibility Triangle. Correct and revise or contact Matthew Flick of Development Services/Engineering @ 791-5640 ext. 1192 to reach an agreement that does not meet Development Standards 3-01.5.0 and to obtain a DSMR. 5. Correct and revise Structural Calculations to indicate changes as per comment #4. |
| 03/15/2005 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T04BU03047 .. 2075 N CALLE CENTRAL .. 1ST REVIEW .. DGL .. 3/16/05 .. S1. Clarify location of retaining wall on site plan C1.0, by dimension from adjacent property lines. S2. Provide elevation of retaining wall, showing grades, length of wall, and daylighting of drain. S3. Provide information required for design of Allan Block Retaining Wall System, ER-5087: 1. Foundation investigation. 2. Federal Highway Administration - Design and Construction Guidelines for Reinforced Soil Structures, Volume I . 3. Allan Block Retaining Walls Design Manual. 4. Provide structural calculations to comply with the ER Report #5087, including global stability and reinforcing requirements. S4. Clarify on drawings, per ER5087, Special Inspection required for: 1. Block placement. 2. Backfill. 3. Geogrid installation, if required by structural calculations. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111. |
| 03/25/2005 | PATRICIA GEHLEN | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/07/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |