Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T04BU02583
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/08/2005 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Grading Plan 1. Include a copy of the stamped approved Site Plan. 2. On the northwest side of the property, an elevation of 2343.70 is dispersing into an alley way, which may cause ponding. Also it appears that the discharge will adversely affect the adjacent property and or structures. The alley runs south to north. It appears that the discharge is to flow westerly. Correct and revise. 3. Submit another copy of the Drainage Report. |
| 03/08/2005 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | DATE: March 14th, 2005 ACTIVITY NUMBER: T04BU02583 PROJECT NAME: Tucson Store Fixtures PROJECT ADDRESS: 504 West Grant Road PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the Storm Water Pollution Prevention Plan (SWPPP). Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: THREE COPIES OF THE GRADING PLAN, NOI AND THE STORM WATER POLLUTION PREVENTION PLAN. 1. The SWPPP can be approved once the grading plan is approved. Please submit three copies of the grading plan, NOI and the SWPPP with the next submittal. |
| 03/19/2005 | DAVID RIVERA | ZONING | REVIEW | Denied | 03/19/05 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved site plan plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved site plan. Additional comments may be forthcoming. |
| 03/28/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit stamped approved site plan including landscape and NPP plans to continue review. |
| 04/01/2005 | PATRICIA GILBERT | NPDES | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/01/2005 | GBONILL1 | APPROVAL SHELF | Completed |
| 04/01/2005 | GBONILL1 | OUT TO CUSTOMER | Completed |
| 04/01/2005 | GBONILL1 | REJECT SHELF | Completed |