Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T04BU02319
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - GRADING ALL

Permit Number - T04BU02319
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2004 Andrew Connor NPPO REVIEW Denied According to approved tentative plat case # S03-047 a separate NPPO plan will be prepared for area indicated on sheet 15 of 32. Include this plan with resubmitted grading plan. Comment must be addressed to continue review.
12/09/2004 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, 12/09/2004, Grading Plan Comments for Sycamore Park Village 2:

1. Lots 17 through 36 do not comply with the differential grading requirements. The submitted justification letter is not sufficient by itself to allow the non compliant fill. Submit a written permission from the impacted adjacent parcel owner (Mr. Ike Isaacson) in which the grade differences are specified (up to 7.00+ in some areas). The permission should not only state that Mr. Isaacson is aware of the work on his parcel, but it should also make it clear that because of this proposed fill on his parcel, lots 17 through 36 of Village 2 of Sycamore Park will be elevated to the proposed heights (as shown on the Grading Plan) and that he permits the proposed grade differential. Please advise Mr. Isaacson that his project may also need a permission letter from the owner(s) of Sycamore Park, Village 2, to allow him exceed the 2' grade difference when he submits his project for review.
2. The grading work on Mr. Isaacson's parcel requires a separate grading permit. Mr. Isaacson needs to submit a grading, SWPPP and NPPO plans for review and approval. Please be advised that the grading work on Mr. Isaacson should be permitted before Village 2 Grading Plan can be approved, otherwise, Village 2 Grading Plan has to be revised to show the work without the grading on Mr. Isaacson Parcel.
12/22/2004 DAVID RIVERA ZONING REVIEW Denied December 22, 2004

Development Services Department
Zoning Review Section

David Rivera
Senior Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning will re-review the grading plans on the next submittal.

3. Please incorporate revised sheet four with the grading plan package.l

Final Status

Task End Date Reviewer's Name Type of Review Description
01/07/2005 LISA LESNY OUT TO CUSTOMER Completed
01/07/2005 SUE REEVES REJECT SHELF Completed