Parcel: 137070470

Review Status: Completed

Review Details: GRADING

Permit Number - T04BU02164
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/02/2004 Joseph Linville NPPO REVIEW Passed
09/20/2004 DOUG WILLIAMS ENGINEERING REVIEW Denied SUBJECT: Site Review - New Senior Center
REVIEWER: Doug Williams
DATE: 20 September 2004
ACTIVITY NUMBERS: T04CM03923/T04BU02164

SUMMARY: Engineering Division has reviewed the Site Plan received on 1 September 2004. No grading plan could be found with the submittal package. Approval of the site plan is not recommended at this time
Please address the following comments in a response letter, and on a revised site plan:

SITE PLAN
1. Sheet C1.1.1 identifies Missiondale Rd. as being vacated yet provides right of way dimensioning. Please revise the plan to reflect current conditions. Provide recording information on the plan for the right of way vacation, if this has occurred.
2. Depict drainage patterns and finished grades (Development Standard - DS - 2-02.2.1.16).
3. Provide estimated cut/fill quantities (DS 2-02.2.1 A17).
4. Provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent, and Benchmark based on City of Tucson Datum, including City Field Book and Page number. Optionally, GPS Control point data may be referenced as a basis of elevation, if - include the basis of elevation on the site plan (DS 2-02.2.1.23).
5. Depict and label roof drainage direction(s)and sidewalk scuppers at all downspout locations for conveyance of 10-year flows, minimum, under all sidewalk areas (DS 2-08.4.1 E & 3-01.4.4 F).
6. Please provide the total area to be disturbed. Should the area be one acre or greater, or if this proposed development is part of a larger common plan, Stormwater Pollution Prevention Plan requirements must be met. See the enclosed flyer, and visit http://www.azdeq.gov/function/forms/appswater.html and http://www.azdeq.gov/environ/water/permits/download/cswppp.pdf for Arizona Pollutant and Discharge Elimination System (AZPDES) guidelines and information, a construction Stormwater Pollution Prevention Plan (SWPPP) checklist, plan preparation and submittal requirements.
* Please note that additional comments may be necessary upon resubmittal, depending upon percent expansion calculation approval by Zoning Review Section, and the nature and extent of revisions that occur to the plans.
* A right of way permit will be required for any work in the public right of way. Contact Permits and Codes - Tucson Department of Transportation (TDOT) at 791-5100 for questions.
If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Doug Williams
Sr. Engineering Associate
Engineering Division
Development Services Department
10/02/2004 DAVID RIVERA ZONING REVIEW Denied October 2, 2004

Development Services Department
Zoning Review Section
David Rivera
Senior Planner

Comments:
1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering Review Section and until all zoning comments or concerns have been addressed.

2. Two copies of the approved and stamped development/site plan, landscape and NPPO plans must be included with grading plan

Final Status

Task End Date Reviewer's Name Type of Review Description
10/04/2004 TAMI ACHONG OUT TO CUSTOMER Completed
10/04/2004 ANGIE SHOFFSTALL REJECT SHELF Completed