Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T04BU02032
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/29/2004 | ANDREW CONNOR | NPPO | REVIEW | Denied | Site plan approval is necessary to complete review. |
| 11/16/2004 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | SUBJECT: Drainage Report, Site, Grading, and Stormwater Pollution Prevention plan review DATE: 16 November 2004 ACTIVITY NUMBERS: T04CM03716/T04BU02032 T15S, R13E, Section 15 Engineering Division has reviewed the Subject items. Approvals of the site and grading plans may not be recommended prior to provision of a minimum recommended setback from the retention/detention basins (ref. Previous drainage report comment # 2), and modifications to the proposed dumpster enclosure. The following comments must be addressed prior to Engineering Division approval: SITE AND GRADING PLANS: 1. Please refer to previous "drainage report" comment #2 - this item must be addressed prior to recommendation for site and grading plan approvals: Discuss and provide recommendations for minimum setbacks from the retention basins for the proposed building, or provide additional geotechnical engineering recommendations - the soils report does not specifically address minimum setbacks, as required per Section14.2.6 of the Drainage Standards Manual (DS 10-02.0). 2. The 14' x 40' clear approach depicted does not allow for a solid waste vehicle to gain access to the point of origin depicted, nor does the proposed location appear to allow for minimum inside and outside turning radii of 36' and 50', respectively. Revise the enclosure angle to allow for direct access to the enclosure from the PAAL/driveway (approximately 30° rather than 45° may allow for such), or provide written approval from Environmental Services Department for the configuration depicted/proposed - preferably on the site plan (DS 2-02.2.1.32 & DS 6-01.4.0). STORMWATER POLLUTION PREVENTION PLAN (SWPPP): 1. Please provide/include page 2 of 2 of the signed Notice of Intent (NOI) in each SWPPP text. 2. Delineate the total area to be disturbed on sheet C5.0 - including the protected material(s) storage area and washout basin areas. These areas should be included in the total area of disturbance calculated. An over-the-counter approval may be coordinated with me if desired, upon completion/provision of the above items. If you have any questions, I can be reached at 791-5550, extension 1189 or Doug.williams@tucsonaz.gov Douglas Williams Sr. Engineering Associate Engineering Division Development Services Department City of Tucson |
| 11/23/2004 | David Rivera | ZONING | REVIEW | Denied | November 23, 2004 Development Services Department Zoning Review Section David Rivera Senior Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering and Landscape Review Section and approval of the site plan. 2. Two copies of the approved and stamped development/site plan, landscape and NPPO plans must be included with grading plan. 3. Zoning will re-review the grading plan on the next submittal to insure compliance with the DSD approved and stamped siter plan. Please include with the next grading plan submittal package two copies of the approved and stamped site, landscape and NPPO plan sheets. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/09/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 12/09/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |