Permit Number: T04BU01506
Parcel: 12418037A

Address:
1436 E 17TH ST

Review Status: Completed

Review Details: GRADING

Permit Number - T04BU01506
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2004 Andrew Connor NPPO REVIEW Approv-Cond Submit approved development plan including landscape and NPP plans to continue review.
07/22/2004 CRAIG GROSS ZONING REVIEW Approved
07/22/2004 ELIZABETH EBERBACH ENGINEERING additional review Approved DATE: July 8, 2004
TO: Mark McCarty, McCarty Engineering
SUBJECT: Arizona Commercial Lighting Grading Plan Review
REVIEWER: Loren Makus
ACTIVITY NUMBER: T04BU01506

SUMMARY: The Grading Plan was reviewed by Development Services Department Engineering Division. The Grading Plan was not approved at this time.

Grading Plan comments:
1) The Development Plan must be approved before the grading plan can be approved. Include a copy of the approved Development Plan with the grading permit application.
2) Include the address for the project.
3) Clearly delineate the grading limits.
4) Include estimated cut and fill quantities and estimated graded area on the grading plan.
5) Reference note #6 in east driveway appears to be misplaced. Please clarify.
6) Provide a wheel barrier to prevent encroachment onto any unsurfaced areas at the south end of the back-up spur. (Development Standard (DS) 3-05.2.2.D

Revise the Grading Plan and SWPPP to address all of these comments and resubmit three copies for review along with a copy of the approved Tentative Plat. If you would like to meet with me to discuss any of these comments please call me at (520) 791-5550 ext. 1161 or email me at loren.makus@tucsonaz.gov.

Loren Makus, E.I.T.
Senior Engineering Associate
Engineering Division
Development Services
07/22/2004 ELIZABETH EBERBACH ENGINEERING additional review Approved SUBJECT: Arizona Commercial Lighting Grading Plan Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: T04BU01506

SUMMARY: The revised Grading Plan was received and reviewed by Development Services Department Engineering Division. The Engineering Division of Development Services Department recommends approval of the Grading Plan.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department
07/22/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Completed DATE: July 8, 2004
TO: Mark McCarty, McCarty Engineering
SUBJECT: Arizona Commercial Lighting Grading Plan Review
REVIEWER: Loren Makus
ACTIVITY NUMBER: T04BU01506

SUMMARY: The Grading Plan was reviewed by Development Services Department Engineering Division. The Grading Plan was not approved at this time.

Grading Plan comments:
1) The Development Plan must be approved before the grading plan can be approved. Include a copy of the approved Development Plan with the grading permit application.
2) Include the address for the project.
3) Clearly delineate the grading limits.
4) Include estimated cut and fill quantities and estimated graded area on the grading plan.
5) Reference note #6 in east driveway appears to be misplaced. Please clarify.
6) Provide a wheel barrier to prevent encroachment onto any unsurfaced areas at the south end of the back-up spur. (Development Standard (DS) 3-05.2.2.D

Revise the Grading Plan and SWPPP to address all of these comments and resubmit three copies for review along with a copy of the approved Tentative Plat. If you would like to meet with me to discuss any of these comments please call me at (520) 791-5550 ext. 1161 or email me at loren.makus@tucsonaz.gov.

Loren Makus, E.I.T.
Senior Engineering Associate
Engineering Division
Development Services
07/22/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Completed SUBJECT: Arizona Commercial Lighting Grading Plan Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: T04BU01506

SUMMARY: The revised Grading Plan was received and reviewed by Development Services Department Engineering Division. The Engineering Division of Development Services Department recommends approval of the Grading Plan.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department

Final Status

Task End Date Reviewer's Name Type of Review Description
07/23/2004 SUE REEVES APPROVAL SHELF Completed
07/23/2004 CINDY AGUILAR OUT TO CUSTOMER Completed