Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T04BU01005
Parcel: 135074580

Review Status: Completed

Review Details: GRADING

Permit Number - T04BU01005
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/05/2004 PAUL MACHADO ENGINEERING REVIEW Denied To: Gregg Carlson, P.E. DATE: May 5, 2004
Gregg Carlson, LLC
1521 E. Broadway Blvd.
Tucson, Arizona 85719
SUBJECT: 8080 E. Research Court
Grading Plan T04BU01005 (First Review)
T14S, R15E, Section 21

RESUBMITTAL REQUIRED: Grading Plan, Drainage Report and SWPPP

The Grading Plan (GP), Drainage Report (DR) and Stormwater Pollution Prevention Plan (SWPPP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Grading Plan:

1. Please include a response letter to the comments along with the corrected copies of the GP.
2. (3) Sets of the grading plan are required on grading submittals.
3. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting".
4. All easement and dedications must be recorded prior to the approval of the grading plan.
5. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1.
6. Please contact Glenn Hicks at 791-4873 x120 for approval of construction in the linear park. Please provide approval letters when obtained.
7. List administrative address/site address on plans.
8. 5' wide conc. sidewalks are required along the r/w per D.S. 3-01.4.0.
9. A permit will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
10. Delineate 100-year W.S.E.L.
11. Call out peak discharges entering and exiting the site.
12. Place all service facilities such as electrical and heating equipment at or above the regulatory flood elevation per Chap. 26 -5.1.11 of the floodplain and erosion hazard management code. Please elevate, as required, the electric transformer adjacent to the refuse containers at the rear of the property.
13. It seems there may be a need to install a depressed curb for the scupper outlets on Research Court or call out handicap ramps if applicable, please explain or address.


Drainage Report:
1. The DR is conditionally accepted. Please address the following comment to satisfy the condition.
2. Please grade basin DA4 to drain. This does not mean out of the basin, but rather to the area of the weir.
3. Please grade basin DA1 to drain and install a bleeder pipe to discharge into the Pantano Wash.
4. The Drainage reports were returned upon completion of this review.

Stormwater pollution prevention plan:
1. The SWPPP has been accepted. Please submit three copies of the SWPPP report with the re-submittal.
2. The SWPPP reports were returned upon completion of this review.


If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
05/18/2004 Joseph Linville NPPO REVIEW Denied Submit approved development plan including landscaping and NPPO plans to continue review.
05/28/2004 DAVID RIVERA ZONING REVIEW Denied May 28, 2004

Development Services Department
Zoning Review Section

David Rivera
Senior Planner

Comments:

A site card with DSD approvals by Fire, Zoning, Handi-cap, Engineering, and Landscape/NPPO including the approved development plan stamped for site plan approval and signatures is required before the grading plan can be approved by Zoning. Two copies of the approved development plan, landscape and NPPO plans are to be submitted with the grading plans packet for processing and approval as a site plan. No fees are involved in re-stamping the development/tentative plat plans as an approved site plan. The development plan, may be walked through for stamps and site card sign off. submit the following: two copies of the stamped development plan, landscape and NPPO plans must be included with the grading plans packet processed together for site approval.

Zoning will review and approve the grading plan upon final approval by the Engineering section.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/01/2004 TAMI ACHONG OUT TO CUSTOMER Completed
06/01/2004 ANGIE SHOFFSTALL REJECT SHELF Completed