Permit Number: T04BU00344
Parcel: 12709007J

Review Status: Completed

Review Details: GRADING

Permit Number - T04BU00344
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/23/2004 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Indicate project address on Sheet 2 and 3. D.S. 2-02.2.1.A.3

2. Indicate location map on Sheet 2 and 3. D.S. 2-02.2.1.A.4

3. Indicate all existing buildings and structures, including roof slope and location of downspouts. D.S. 2-02.2.1.A.6 NOTE: All roof spouts will be routed under any adjacent sidewalk. Sidewalks shall be flood free for all storm discharges of up to a ten (10) year flood event. Indicate roof direction/drainage. D.S. 2-08.3.1 & 4.1.E

4. Indicate drainage patterns, proposed finish floor elevation(s) and finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16

5. Indicate if street is Public or Private. Street ? is a MS&R with Future R.O.W. of ? which intersects with ? , requiring a widening of ? Alley access is not allowed. Align driveway access to existing driveway across the street. Closed unused driveways. Show adjacent driveways. Show existing road medians. D.S. 2-02.2.1.A.18

6. Indicate recording docket and page reference for easement. D.S. 2-02.2.1.A.20

7. The standard dimensions for a refuse enclosure interior is 10' x 10'. Sheet 1, Detail Trash Enclosure indicates interior dimensions to be 12' x 11', which is acceptable.

8. Indicate activity number T04CM00716 on Sheets 1 to 5. Indicate activity number T04BU00344 to Sheets 3 to 5.

9. The spot grades in the pedestrian pathway indicate ponding. Indicate direction of drainage flow.
03/11/2004 JOE LINVILLE NPPO REVIEW Approved
03/15/2004 DAN CASTRO ZONING REVIEW Denied Zoning will review grading plan when site plan is approved by all sections.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/16/2004 TAMI ACHONG OUT TO CUSTOMER Completed
03/15/2004 SUE REEVES REJECT SHELF Completed