Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03OT02244
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/13/2004 | Loren Makus | ENGINEERING | REVIEW | Denied | DATE: January 13, 2004 TO: Kent Delph, Delph Engineering SUBJECT: Mitchell Addition Lots 1-4, Grading Plan and Site Review REVIEWER: Loren Makus ACTIVITY NUMBERS: T03BU02009 and T03OT02244 SUMMARY: The Grading Plan and Site Plan were reviewed by Development Services Department Engineering Division. The Grading Plan and Site Plan were not approved at this time. Grading/Site Plan comments: 1) Show lot and roof drainage for all lots. Show positive drainage away from all foundations. 2) Label the water surface elevation and low point at the wash crossing in the driveway of lot 2. Show that the wash crossing provides all weather access. 3) Provide a cross access easement for lots 3 and 4 for the shared driveway. Show the easement and recordation information on the plan. Revise the Grading/Site Plan to address all of these comments and resubmit two copies for review along with a copy of the approved development plan. If you would like to meet with me to discuss any of these comments please call me at (520) 791-5550 ext. 1161. Loren Makus Senior Engineering Associate Engineering Division Development Services |
| 01/14/2004 | PETER MCLAUGHLIN | HANDICAP-SITE | REVIEW | Passed | |
| 01/14/2004 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Kent A Delph 221 N. Court Ave Ste 103 Tucson, AZ 85714 FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: T03OT02244 Mitchell Addition, Lots 1-4 South 6th Avenue and Aragon Road TRANSMITTAL: January 14, 2004 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Revise the adjacent zoning to the east to read "R-2". DS 2-02.2.1.A.28 2. Label the centerline for S. 12th Avenue and for Aragon Road along with the existing curb. DS 2-02.2.1.A.19 3. Add the development designator "O" for the proposed use to the zoning data table. LUC 2.5.3.2.E.1 4. Add existing and future sight visibility triangles to the drawing at the intersection of 6th Ave and Aragon Road. Also, revise paving note #15 by removing reference to Broadway Blvd and adding 6th Ave. DS 2-02.2.1.A.10 5. A cross access agreement must be recorded for the shared drive between lots 3 and 4. Label the easement and add recordation information to the site plan. DS 2-02.2.1.A.20 6. It is stated in the Zoning Data Table notes that the height of the structures is 14 feet along all four exterior walls. The required perimeter yard setback to adjacent R-2 zoned property (to the east) is the greater of 10 feet of ¾ the height of building walls. With a proposed height of 14 feet, the required bldg setback to the east perimeter yard is 10.5 feet. Revise the plan by dimensioning this required bldg setback and revise the location of buildings on lots 1 and 2 to demonstrate compliance. LUC 3.2.6.4 7. State the existing use of the property on the site plan (i.e. vacant). DS 2-02.2.1.A.31 8. Add the lot dimensions to the west property lines of each of the four individual lots. 9. The site is located with the Airport Hazard District (AHD) of the Airport Environs Overlay Zone. Correct the notes under each lot in the Zoning Data Table, which state that no overlay zones apply. Add a note stating that the development is subject to LUC Sec 2.8.5, and is within the Airport Hazard District of the Airport Environs Overlay Zone. Add an Airport Hazard District note to indicate that the elevation above median sea level (MSL) of the NW end of runway 11R is 2,583 feet and that the elevation of the subject properties above MSL are approximately 2,530. LUC 2.8.5 LUC 2.8.5.7.A.1 10. As noted on the plan, 6th Avenue is a designated MS&R Add a statement that the plan is in compliance with LUC 2.8.3, Major Streets and Routes Setback Zone. LUC 2.8.3 11. Revise the legal description for lot 1 under the Zoning Data Table to read "Block 2". DS 2-02.2.1.A.2 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 01/14/2004 | Joseph Linville | LANDSCAPE | REVIEW | Passed | |
| 01/15/2004 | JOE LINVILLE | NPPO | REVIEW | Passed | |
| 01/16/2004 | JIM EGAN | FIRE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/20/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 01/20/2004 | TAMI ACHONG | REJECT SHELF | Completed |