12/15/2003 JIM TATE ENGINEERING REVIEW Denied DATE: December 15, 2003
ACTIVITY NUMBER: T03OT02119
PROJECT NAME: Patricia Parra Manufactured Home
PROJECT ADDRESS: 3125 N. Estrella Avenue No. 5
PROJECT REVIEWER: James C. Tate, P.E., CFM


A Flood Use Permit is denied.

The following items must be revised or added to the plan. Please include a response letter with the next submittal that states how all comments have been addressed.

Resubmittal Required: Flood Use Permit Application and Plans

1. The structural details provided with the Flood Use Permit application are for the masonry skirting only. The masonry skirting is designed to resist horizontal forces (wind, earthquake, eath), but not vertical loads. The foundation elements beneath the manufactured home carry the vertical load. The details provided say, "interior foundation by others". Please provide the structural details for the interior foundation.