Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T03OT02119
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/15/2003 | JIM TATE | ENGINEERING | REVIEW | Denied | DATE: December 15, 2003 ACTIVITY NUMBER: T03OT02119 PROJECT NAME: Patricia Parra Manufactured Home PROJECT ADDRESS: 3125 N. Estrella Avenue No. 5 PROJECT REVIEWER: James C. Tate, P.E., CFM A Flood Use Permit is denied. The following items must be revised or added to the plan. Please include a response letter with the next submittal that states how all comments have been addressed. Resubmittal Required: Flood Use Permit Application and Plans 1. The structural details provided with the Flood Use Permit application are for the masonry skirting only. The masonry skirting is designed to resist horizontal forces (wind, earthquake, eath), but not vertical loads. The foundation elements beneath the manufactured home carry the vertical load. The details provided say, "interior foundation by others". Please provide the structural details for the interior foundation. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/15/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 12/15/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |