Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T03OT01856
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/11/2004 | Doug Williams | ENGINEERING | REVIEW | Approved | |
| 03/18/2004 | Andrew Connor | LANDSCAPE | REVIEW | Approv-Cond | Condition: Must have irrigation system installed. |
| 03/18/2004 | Andrew Connor | NPPO | REVIEW | Approved | |
| 03/19/2004 | Peter McLaughlin | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Greg Carlson 1521 E. Broadway Blvd Tucson, AZ 85719 (520) 624-0070 FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner Development Services Dept. PROJECT: T03OT01856 Eagle Appliances 727 W. Irvington Road Site Plan Review (3rd review) TRANSMITTAL: March 22, 2004 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The length of parallel vehicle parking spaces such as the three shown adjacent to the near the east property line is required to be 23 feet. These three spaces dimension to only about 22 feet on the drawing and the dimension arrow, which are not placed correctly, reads "9 feet x 20 feet typ". Revise to meet standard and position dimension arrow correctly on the drawing. DS 3-05.2.1.B.2 2. Based on the class 2 bicycle parking detail there is not enough room to fit the two proposed posts to park four bikes as shown in front of the vehicle parking space. A wheelstop curb must be placed in this proposed vehicle space to allow overhang of parked vehicle and to prevent the vehicle from striking parked bicycles. Revise the length of the bicycle to be 6 feet on the bicycle parking detail. Revise the detail to be consistent with the calcs which indiate only two bicycle parking spaces are provided/ required. Also, add a dimensioned 5-foot maneuverability area on the bicycle parking detail plan per DS 2-09. DS 2-09 DS 3-05.2.3.C.1 3. Revise MS&R setback to be dimensioned from back of future curb location rather than back of existing curb location. DS 2-02.2.1.A.19 DS 2-02.2.1.A.10 4. Revise note 21 to read "Sec. 2.8.3" rather than "Sec. 28.3". LUC 2.8.3 5. Remove the word "unless" from the "6 inch reveal" label in monolithic curb detail. 6. The adjacent zoning indicator labels are too light. Darken them so that they will reproduce and be more legible for microfilming and archiving purposes. DS 2-02.2.1.A.28 7. The required parking calculation may be rounded down to 7. LUC 3.3.3.8 8. Revise h/c parking calculation to read 1/25 rather than 1/50. IBC 9. Revise the 2-½ foot dimension to be from the front (wheel side) of the wheel stop curb in the parking space typical. DS 3-05.2.3.C If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/22/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 03/22/2004 | SUE REEVES | REJECT SHELF | Completed |