10/17/2003 Patricia Gilbert ENGINEERING REVIEW Denied DATE: October 27, 2003
ACTIVITY NUMBER: T03OT01840
PROJECT NAME: University Car Wash
PROJECT ADDRESS: 1525 North Park Avenue
PROJECT REVIEWER: Patricia Gilbert

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. Basis of bearing is required. Include bearings on the site plan. Dimension the northeast corner. DS 2-02.2.1.A.5.

2. Points of egress and ingress including locations and width of driveways and parking area access lanes (PAALs) are required. Per Chapter 25-38 of the Tucson City Code the Maximum curb width is 35'. Dimension the ingress/egress for the PAAL off of Park Ave. DS 2-02.2.1.A.11.

3. Include drainage patterns (lot, street and roof drainage), proposed finish floor elevation(s), and finish grades. DS 2-02.2.1.A.16.

4. Include existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. DS 2-02.2.1.A.23.

5. A 6' sidewalk is required on all new development on a Major Street & Route (MS&R) per the MS&R Plan. The sidewalk must be located in the ROW. Locate the new sidewalk to the future curb location. Revise plan as necessary.
10/17/2003 Patricia Gilbert SANITATION REVIEW Denied
11/13/2003 Daniel Castro ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next
Submittal, which states how all Zoning Review Section comments Regarding the Land Use Code and Development Standards were Addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Per Pima County Assessors Records, the site is comprised of two separate parcels which must be combined by providing a copy of the recorded City of Tucson Lot Combination Covenant and a copy of the approved Pima County Assessors Tax Combination form. Attached to the yellow site plan card is a copy of the City of Tucson Lot Combination Covenant. Contact the Assessors office for a copy of the Tax Combination form.

2. Add the following general note: "Bicycle parking not required." (D.S. 2-02.2.1.A.9)

3. This plan may be reviewed over the counter by the Zoning Review Section. Please contact Dan Castro to set an appointment.


If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
11/14/2003 DAN CASTRO HANDICAP-SITE REVIEW Passed
11/17/2003 Joseph Linville LANDSCAPE REVIEW Denied 1) The street landscape borders are required to be a minimum of ten feet wide as measured from the street property lines, unless the City Engineer approves up to five feet in the public right of way. Provide verfication, in writing, of any approvals obtained. LUC 3.7.2.4.A.1

2) Plumbago auriculata is not on the approved plant list. Only plants from the list may be used in the street landscape borders. LUC 3.7.2.2.C.3, DS 9-06

3) A summary of native plant requirements is required to be included onthe landscape plan. DS 2-15.3.4.B

4) A minimum distance of two (2) feet must be maintained between a PAAL and any wall, screen, or other obstruction, provided pedestrian activity is directed to another location. The additional area is necessary to provide clearance for fire, sanitation, and delivery vehicles per DS 3-04.2.2.B.3.

Revise the plan to provide the 2' distance between the paals and any screen walls.
11/17/2003 JOE LINVILLE NPPO REVIEW Denied Submit a native plant preservation plan or application for exception.
11/20/2003 JIM EGAN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
11/20/2003 DELMA ROBEY OUT TO CUSTOMER Completed