Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T03OT01156
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/03/2003 | LOREN MAKUS | ENGINEERING | REVIEW | Approv-Cond | The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: Parcel 118-04-198C at 1871 S. San Antonio Drive, in a portion of Township 14 South, Range 13 East, Section 22, recorded in Docket 11831 Page 12722, for the purpose of constructing four duplexes, driveway, and retention/detention facilities. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 8 conditions apply to this permit. (see Tucson Code of Ordinances Chapter 26) 1) All work shall conform to the attached Greg Carlson Engineering Grading Plan (dated 6-24-03), and Greg Carlson Engineering drainage report (dated 11-22-02), which are made part of this permit. 2) Any building shall be placed on a engineered pad, compacted to 95% density, extending twenty-five (25) feet beyond the buildings foundation, unless a study prepared by a state-registered professional civil engineer and approved by the city engineer shows that a lesser distance is acceptable. 3) The existing drainage patterns at the property lines shall not be obstructed. 4) Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T03OT01156. FOR INFORMATION PLEASE CALL 791-5550." 5) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 6) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the structure and / or site development. 7) Any walls to be constructed will require a separate grading and building permit. The retaining wall along the driveway and the retention basin will be completed before the construction of any other structures. 8) A Right-of-way Use Permit is required for any erosion protection construction or other construction in within the right of way. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section. (EXPIRATION DATE) Month: 7 Day: 2 Year: 2004 Note: Final inspection or certificate of occupancy will be on hold until the Elevation Certificate is completed and returned to our office. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/03/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |
| 07/03/2003 | ANGIE SHOFFSTALL | APPROVAL SHELF | Completed |