Permit Number: T03OT00638
Parcel: 14108522A

Review Status: Completed

Review Details: SITE

Permit Number - T03OT00638
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/15/2003 JIM EGAN FIRE REVIEW Approved
04/25/2003 JOE LINVILLE NPPO REVIEW Denied The NPPO submittal must include a plant preservation and salvage plan and a salvage and mitigation report.
DS 2-15.3.4

The submittal must also include a copy of the previously approved plans for comparison with the revised plans.
04/25/2003 JOE LINVILLE LANDSCAPE REVIEW Denied Include a summary of any plants required to meet the requirements of the NPPO Plan. Show the disposition of any
PIP, TOS, and required mitigation. DS 2-15.3.4.B.2
See NPPO comments.

The loading areas must be screened from the street per LUC Table 3.7.2-I with a six foot high masonry wall.
05/02/2003 DAN CASTRO HANDICAP-SITE REVIEW Passed
05/02/2003 DAN CASTRO ZONING REVIEW Approved
05/05/2003 PAUL MACHADO ENGINEERING REVIEW Denied To: James R. Watson
Architect
5672 E. Kelso Street
Tucson, Arizona 85712

SUBJECT: 6800 E. Century Park Drive
Site plan T03OT00638 (First Review)
T15S, R15E, Section 18

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement.

The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies with resubmittal.
2. A rough grading plan only exists under T00CM02665. A separate grading submittal is required.
3. It appears that the lot coverage calculations in the DS differ from the lot calculations on the SP. Please address.
4. Total lot coverage calculation should be calculated per lot, unless a lot combination has been applied for.
5. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
6. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17.
7. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
8. A private improvement agreement or permit will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
9. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable.
10. List the consulting engineer and the owner/developer on the plans with the pertinent information.
11. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
Drainage Statement:
1. It appears that the lot coverage calculations in the DS differ from the lot calculations on the SP. Please address.
2. Total lot coverage calculation should be calculated per lot, unless a lot combination has been applied for.
3. Please state in the DS that you have reviewed the data in the report by Jerry Jones & Assoc. and agree to the data.
If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
05/06/2003 ANY SANITATION REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
05/29/2003 TAMI ACHONG OUT TO CUSTOMER Completed
05/06/2003 ANGIE SHOFFSTALL REJECT SHELF Completed