Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03OT00479
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/26/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 04/07/2003 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Scale reads 1"=20' but it measures 1"=10'. Correct and revise. D.S. 2-02.2.1.A.1 2. Indicate existing and future sight visibility triangles. D.S. 2-02.21A.10 3. Indicate limits of the 100-year floodplain and water surface elevation (when applicable). D.S. 2-02.2.1.A.15 4. Indicate drainage patterns. D.S. 2-02.2.1.A.16 5. Indicate estimated cut and fill quantities. D.S. 2-02.2.1.A.17 6. Indicate if streets are "Private or Public". D.S. 2-02.2.1.A.18 7. Indicate dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. Indicate Grant Road right-of-way. D.S. 2-02.2.1.A.19 8. Indicate all easements of record must be graphically shown on the plan together with recording docket and page reference if applicable. D.S. 2-02.2.1.A.20 9. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. Future sidewalk area is 12' with a 6' wide sidewalk. D.S. 2-02.2.1.A.21 10. Indicate existing and proposed refuse container location, size and access thereto fully dimensioned. D.S. 2-02.2.1.A.32 11. Indicate correct keynote numbers to identify correct items. 12. Keynote 33 indicates a new 5' fence. Indicate what type of material will be used. 13. Indicate location of the transition for the existing to the proposed wall. Indicate base type the wrought iron fence will use (retaining wall/sidewalk)? 14. Check with DOT/Traffic Engineering for alley access. Drainage Report 1. A Floodplain Use Permit is required for new construction/development in a FEMA floodplain. Application is attached to reviewer's comments. If missing, an application can be picked up at the engineering counter Dev. Serv. Dept. 1st floor. |
| 04/09/2003 | BLANCA ESPINO | SANITATION | REVIEW | Denied | Site Plan 1. Indicate existing and proposed refuse container location, size and access thereto fully dimensioned. D.S. 2-02.2.1.A.32 |
| 04/17/2003 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | Zoning 4/21/2003 Although a Board of Adjustment variance was obtained in 1991 for an office use, the 1995 letter from Walter Tellez, the zoning administrator, indicates the use was changed to a Bed and Breakfast (sign on the property would also support a Bed and Breakfast Use). With the change to Bed and Breakfast, the variance and non-conforming status of the office use was lost. To convert back to office use, a full code compliance review will be require. Use of an alley for vehicle movement is not permitted for commercial uses. Please provide copies of the last CofO for this site. Since this is a change of use, a site plan review fee will be required once the plans are resubmitted. |
| 04/21/2003 | PATRICIA GEHLEN | HANDICAP-SITE | REVIEW | Denied | Please see Zoning commets. Until the type of review required, comments may not be made. |
| 04/23/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Plantings as shown on the 1993 plan in the area between the existing wall and the sidewalk along Rainbow Vista Drive are still required. Revise the plan to include all plantings included on the previous plans. 2) The proposed loading zone along Grant Road requires screening per LUC Table 3.7.2-I. The loading area must be screened from Rainbow Vista Drive and Grant Road with a 6' high masonry wall. Wall locations may be restricted based on sight visibility requirements for the future right of way. 3) Identify the height of the wall referred in keynote 33. The height should be more than 30 inches to maximize visibility. DS 3-01.5.1 4) Clarify if the existing walls (keynote 3) are being replaced with the new wrought iron fence (keynote 30). The fencing was not approved as part of the variance case. This will require a new variance case. The minimum screening requirements for parking lots per LUC table 3.7.2-I also apply to the site. Revise the plans as necessary. |
| 04/23/2003 | JOE LINVILLE | NPPO | REVIEW | Approved | exception. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/15/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |