Permit Review Detail
Review Status: Completed
Review Details: SITE-REVISION
Permit Number - T03OT00445
Review Name: SITE-REVISION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/09/2003 | Blanca Espino | ENGINEERING | REVIEW | Denied | Site Plan 1. Indicate roof slope and downspouts on all existing and proposed buildings and structures. Indicate sidewalk scuppers and riprap with details if applicable. D.S. 2-02.2.1.A.6 2. Indicate and label future sight visibility triangles. D.S. 2-02.2.1.A.10 3. All easements of record must be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20 4. Indicate dimensions from street monument lines to proposed curbs, sidewalks, driveways and utility lines. D.S. 2-02.2.1.A.21 5. Indicate refuse container location, size, gates and access thereto fully dimensioned. D.S. 2-02.2.1.A.32 6. A Lot Combination and Cross Access Agreement are required. |
| 09/12/2003 | BLANCA ESPINO | SANITATION | REVIEW | Denied | 1. Indicate refuse container location, size, gates and access thereto fully dimensioned. D.S. 2-02.2.1.A.32 |
| 10/10/2003 | Daniel Castro | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. Provide a copy of the recorded City of Tucson lot combination covenant and a copy of the approved Pima County Assessors Tax Combination form. Site plan may not be approved until these documents have been provided. (D.S. 2-02.2.1.A.2) 3. Provide the residential density calculation. 4. LUC Sec. 3.3.4 "Multi-family Dwellings" requires 1.5 spaces per unit for a one-bedroom unit. Two (2) one-bedroom units require three (3) vehicle parking spaces. Delete the visitor parking space from the required parking calculation as it is not required. Note the total number of vehicle parking spaces provided for the residential units. (D.S. 2-02.2.1.A.8) 5. Correct the net area square footage. (D.S. 2-02.2.1.A.8) 6. Restrooms and platform must be included in the commercial vehicle parking calculation. (D.S. 2-02.2.1.A.9) 7. Provide a copy of the last approved site plan and vehicle parking calculation for the banquet hall to verify if sufficient vehicle parking may be used for the proposed site. The Banquet Hall is parked at one (1) space per 50 square feet of gross floor area. Once the vehicle parking calculation has been verified by the Zoning Review Section, a copy of the recorded cross access agreement must be provided for Development Services Department records. (D.S. 2-02.2.1.A.11) 11. Under note number one (1), the residential use is listed as Family Dwelling RCP-9. This review is based on Multi-family residential development designator O. Please note the proposed residential land use as "Family Dwelling development designator O". If the site is proposed as an RCP, a tentative plat and final plat will be required. (D.S. 2-02.2.1.A.31) 12. All requested changes must be made to the site and landscape plans. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 10/13/2003 | DAN CASTRO | HANDICAP-SITE | REVIEW | Approved | |
| 10/16/2003 | Joseph Linville | LANDSCAPE | REVIEW | Denied | 1) Lawn area is restricted to 571 sq. ft. if planted with non drought tolerant plants. LUC 3.7.2 2) Wheel stops added along Limberlost are now unnecessary due to approval for right of way landscaping. Revise the plans to remove these items providing the necessary parking space dimensions. |
| 11/13/2003 | JIM EGAN | FIRE | REVIEW | Approv-Cond | Fire approval for site access and fire hydrant locations only. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/25/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 11/13/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |