Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03OT00419
Parcel: 10705102A

Address:
2901 N ORACLE RD

Review Status: Completed

Review Details: SITE

Permit Number - T03OT00419
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/13/2003 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next
Submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Provide a fully dimensioned detail of the handicap parking space ramp. Refer to ANSI A117.1-1998 Sections 406 and 502. Indicate the slope of ramp, direction of slope, and width of sidewalk. (D.S. 2-02.2.1.A.8)

2. Per LUC Sec. 3.3.3.5, If the calculated number of required bicycle parking spaces is less than two (2), the minimum number of required spaces is two (2). You may substitute Class II spaces for Class I. Revise parking calculation as required. (D.S. 2-02.2.1.A.9) (D.S. 2-02.2.2.A.4)

3. Per LUC Table 3.3.7-I (90 degree) parking space must have a 24 foot wide PAAL. The farthest space to the east does not have 24 feet behind it, revise as required. (D.S. 2-02.2.1.A.11)

4. If applicable, provide a detail of existing and/or proposed free standing signage, billboard, and outdoor lighting on the site plan. (D.S. 2-02.2.2.1.A.13) (D.S. 2-02.2.1.A.25)

5. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference. (D.S. 2-02.2.1A.20)

6. Under the proposed land use block please add the "subject to Sec. 3.5.9.2.A." (D.S. 2-02.2.1.A.31)

7. The previous comments may be reviewed by the Zoning Review Section over the counter. Please contact Dan Castro to set an appointment.

8. All requested changes must be made to the site and landscape plans.

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
05/16/2003 DAN CASTRO HANDICAP-SITE REVIEW Denied Provide a fully dimensioned detail of the handicap parking space ramp. Refer to ANSI A117.1-1998 Sections 406 and 502. Indicate the slope of ramp, direction of slope, and width of sidewalk. (D.S. 2-02.2.1.A.8)
05/16/2003 JOE LINVILLE LANDSCAPE REVIEW Approved
05/19/2003 PATRICIA GEHLEN NPPO REVIEW Approved exc.
05/19/2003 JIM TATE ENGINEERING REVIEW Denied DATE: May 19, 2003
ACTIVITY NUMBER: T03OT00419
PROJECT NAME: Modular for Pottery
PROJECT ADDRESS: 2901 N. Oracle Rd.
PROJECT REVIEWER: James C. Tate, P.E.

Resubmittal Required: Site Plan

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

1. It is not clear on the plan if the sidewalk along the street frontages is existing or proposed or some of both. The existing sidewalk can remain in its current location. However, any new sidewalk must meet standards. Any new sidewalk along Oracle must be 6 ft. wide. All new sidewalk must be located 3 ft. from back of curb. Also, sidewalk is required along the entire Laguna street frontage. The plan shows sidewalk along just the proposed developed area of the lot. This is incorrect. Show sidewalk along the entire frontage. Label and dimension both existing and proposed sidewalks

2. The plan shows both a 28 ft. and 20 ft. ½ right-of-way for Laguna. It appears that the 20 ft. ½ R.O.W. is incorrect. It appears that this dimension is actually to face of curb. Correct.

3. Oracle is an MS&R route. Because of the intersection with Miracle Mile the standard MS&R width for Oracle does not apply. Obtain written approval from Tucson Department of Transportation for the proposed street design and width.

4. Place a note on the plan that all roof downspouts will be routed under any adjacent sidewalk. Sidewalks must be flood free for up to the ten year event. DS 2-08.4.1.E
05/19/2003 JIM TATE SANITATION REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
05/21/2003 TAMI ACHONG OUT TO CUSTOMER Completed