Review Date Reviewer's Name Type of Review Description Status Comments
03/16/2004 BOB SUBA ELECTRICAL-COMMERCIAL REVIEW Approved
03/16/2004 Doug Laakso BUILDING-COMMERCIAL REVIEW Denied .. T03CM05905 .. 9525 E OLD SPANISH TRAIL #117 .. DGL
.. INITIAL REVIEW .. 3/18/04 .

S1. Provide completed Code Review Checklist.
S2. Provide copy of Official Address Slip from Pima County Addressing .
S3. Provide documents, including drawings with a minimum
of ten point font.
S4. Provide exit corridor directly to the outside with walls separating from other uses.
S5. Provide copies of all prior submittals for reference.
S6. Fully dimension toilet rooms, including fixture locations,
floor plan and elevations, including access to toilet rooms from retail area to show conformance with
IBC Sec #11 and ANSI A117.1-1998 ed, show required clear floor space.
S7. Detail brace and metal stud connections to wood truss/plywood roof above, including blocking,etc.
S8. Provide details for toilet room ceilings.
S9. Provide adequate details and dimensions to show cash wrap conforms to IBC Sec #11 and ANSI
# A117.1-1998ed.
S10. Provide note on drawings addressing accessibility per
IBC Sec #11 and ANSI #A117.1-1998ed. Does site,
building and tenant space comply?
S11. Provide note on drawings, at exit door #6, per IBC
Sec #1003.3.1.8, " THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED".
S12. Separate Sign Permits required for signs.
S13. Separate Building Permits required for storage racks over eight feet high.

Questions? Call Douglas Laakso, COT-DSD Structural Plans Examiner, at (520) 791-5550 x 1111.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/30/2004 EGRANT1 OUT TO CUSTOMER Completed
03/18/2004 ANGIE SHOFFSTALL REJECT SHELF Completed