Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM05729
Parcel: 120031440

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T03CM05729
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/15/2003 GERRY KOZIOL WWM REVIEW Approved
12/29/2003 Bruce Stevens BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS PROJECT #T03CM05729
12/31/2003 840 W. President St.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.
GENERAL REQUIREMENTS:
1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.
2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.
STRUCTURAL PLANS:
1. SPECIFY LATERAL SUPPORT OF TRUSSES.
2. DETAIL GABLE END BRACING CONNECTIONS.
3. SPECIFY AND DETAIL ALL OVER FRAMING. IF SOLID SHEATHING IS USED ON THE LOWER TRUSSES, PROVIDE MINIMUM OPENINGS OF 22" BY 30" FOR ACCESS AND VENTILATION INTO OVER FRAMED AREAS (>30 S.F.). IF SOLID SHEATHING IS NOT USED ON LOWER TRUSSES, PROVIDE DETAILS FOR BRACING OF TOP CHORD OF LOWER TRUSSES.
4. COMPLETELY DETAIL ALL CONNECTIONS AND CROSS-REFERENCE TO THE FOUNDATION AND FRAMING PLANS:
- BEAM TO POST
- POST TO SLAB

5. DETAIL CONSTRUCTION OF BEAM POCKETS AT PORCH BEAM.
SECTIONS - DETAILS - MISC. NOTES:
1. SHOW HOW YOU WILL GROUT THE ANCHOR BOLTS AT THEIR CONNECTION TO EXISTING MASONRY WALL.
PLUMBING PLANS:
1. NOTE AND SPECIFY ALL PIPING MATERIALS.
2. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE.
MECHANICAL PLANS:
1. SHOW HOW THE EXISTING HEATING SYSTEM WILL PROVIDE THE ADDITION WITH HEATING CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 68 DEGREES AT A POINT 3' ABOVE THE FLOOR PER R303.6.
ELECTRICAL PLANS:
1. BATHROOM OUTLETS SHALL BE ON A SEPARATE 20 AMP CIRCUIT WITH NO OTHER OUTLETS, PER E33603.4. IDENTIFY THIS CIRCUIT ON THE PANEL SCHEDULE.
2. ELECTRICAL LOAD CALCULATIONS ARE REQUIRED WHEN MORE THAN 4 CIRCUITS ARE ADDED.
3. SUBMIT PANEL SCHEDULE SHOWING CIRCUIT AMPACITY, WIRE SIZES, PANEL SIZE AND CIRCUIT NUMBERS.
4. EXISTING BEDROOMS SHALL BE EQUIPED WITH BATTERY OPERATED SMOKE DETECTORS PER R317.1.1.
IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
BRUCE STEVENS @ 791-5550 EXT. 1174

Final Status

Task End Date Reviewer's Name Type of Review Description
01/06/2004 TAMI ACHONG OUT TO CUSTOMER Completed
12/31/2003 ANGIE SHOFFSTALL REJECT SHELF Completed